Model Number IPN000263
Device Problems Material Puncture/Hole (1504); Gas/Air Leak (2946)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 07/20/2020
Event Type  malfunction  
Manufacturer Narrative
(b)(4).
 
Event Description
It was reported that the intra-aortic balloon (iab) was implanted normally, and the intra-aortic balloon pump (iabp) was started.The iabp could not be started and alarmed for a "helium leak".The iab was repositioned repeatedly, and the balloon size was adjusted, with no change.As a result, the iab was removed and a new iab was used, using the same insertion site.There was no report of patient complications, serious injury or death.
 
Event Description
It was reported that the intra-aortic balloon (iab) was implanted normally, and the intra-aortic balloon pump (iabp) was started.The iabp could not be started and alarmed for a "helium leak".The iab was repositioned repeatedly, and the balloon size was adjusted, with no change.As a result, the iab was removed and a new iab was used, using the same insertion site.There was no report of patient complications, serious injury or death.
 
Manufacturer Narrative
(b)(4).Teleflex received the device for investigation.The reported complaint of iab leak suspected is confirmed.During the investigation, a puncture to the bladder, consistent with contact from a sharp object, was found on the bladder membrane which caused the helium loss alarm and could allow blood to enter the helium pathway.No other leaks were detected during functional testing.The root cause of the bladder leak is undetermined.A potential cause is customer handling.A device history record (dhr) review was conducted for the lot number with no relevant findings.The device passed all manufacturing specifications prior to release.Teleflex assessed the risk for the reported complaint.There are no new or revived risk.This will be monitored for any developing trends.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
REDIGUARD IAB: 8FR 40CC
Type of Device
SYSTEM, BALLOON, INTRA-AORTIC
Manufacturer (Section D)
ARROW INTERNATIONAL INC.
reading PA
MDR Report Key10548909
MDR Text Key207393295
Report Number3010532612-2020-00253
Device Sequence Number1
Product Code DSP
UDI-Device Identifier00801902002679
UDI-Public00801902002679
Combination Product (y/n)N
PMA/PMN Number
K981660
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,distri
Type of Report Initial,Followup
Report Date 08/26/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received09/17/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date12/31/2021
Device Model NumberIPN000263
Device Catalogue NumberIAB-S840C
Device Lot Number18F20A0038
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/06/2020
Date Manufacturer Received10/15/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Age57 YR
Patient Weight64
-
-