| Model Number |
N/A |
| Medical Device Problem Codes |
Crack (1135); Fluid/Blood Leak (1250)
|
| Health Effect - Clinical Code |
No Consequences Or Impact To Patient (2199)
|
| Date of Event |
08/18/2020
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
The manufacturer has received the sample and will evaluate.Results are expected soon.A lot history review (lhr) review is not possible, as no manufacturing lot number has been provided by the complainant.
|
| |
|
Event or Problem Description
|
|
It was reported "we had a patient come to the unit with a cracked y-site.We hooked up her 5-fu pump around 4:15pm yesterday and she said it was fine until ~12:30 she had noticed it was leaking blood.The line was flushed the and that¿s when it was noted that the hub closest to the patient was cracked and leaking.¿.
|
| |
|
Additional Manufacturer Narrative
|
|
H11:section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.The following were reviewed as part of this investigation: patient severity, trend analysis, applicable previous investigation(s), sample (if available), and applicable fmea documents.Based on a review of this information, the following was concluded: the complaint of a cracked y-site was confirmed and the cause was supplier-related.The product returned for evaluation was one 20ga x 1¿ miniloc safety infusion set.Usage residues were observed throughout the sample and the safety mechanism was engaged.A longitudinally aligned split was observed in the y-site.Microscopic inspection of the split revealed a granular fracture surface.Discoloration and abundant superficial stress cracking were observed in the vicinity of the split.The split propagated along a molding weld line.The split propagated along a molding feature, indicating that features created during the molding process caused the observed fracturing.The stress fracturing observed further suggested that some part of the manufacturing process affected the mechanical properties of the y-site material.The device is a supplied component and the supplier has been notified of this event.A lot history review (lhr) review is not possible, as no manufacturing lot number has been provided by the complainant.
|
| |
|
Event or Problem Description
|
|
It was reported "we had a patient come to the unit with a cracked y-site.We hooked up her 5-fu pump around 4:15pm yesterday and she said it was fine until ~12:30 she had noticed it was leaking blood.The line was flushed the and that¿s when it was noted that the hub closest to the patient was cracked and leaking.¿ additional information received stated, "patient had chemotherapy leak on them, precautions were taken.".
|
| |
|