Model Number 0070800
Medical Device Problem Code Incorrect Measurement (1383)
Health Effect - Clinical Codes No Consequences Or Impact To Patient (2199); Insufficient Information (4580)
Date of Event 08/07/2020
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.
 
Event or Problem Description
It was reported that the balloon burst on the 6th day of use.Per additional information received from ibc via mail on 02sep2020, the balloon burst in the bottle.
 
Additional Manufacturer Narrative
The reported event was confirmed as manufacturing-related.An evacuator was returned without its original packaging.The balloon was found to be burst.On (b)(6) 2020, the balloon was obtained to measure the thickness of the portions of the balloon that burst to determine if there was a manufacturing defect.Measurement varied from 0.0485"-0.0640".As there were measurements were found above 0.058" the device was found to fail specifications.A potential root cause could be due to an "operator error" during the latex dipping.The lot number was unknown; therefore, the device history record could not be reviewed.As the reported event was confirmed as manufacturing related, a labeling review was not performed.H11:section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
 
Event or Problem Description
It was reported that the balloon burst on the 6th day of use.Per additional information received from ibc via mail on 02sep2020, the balloon burst in the bottle.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RELIAVAC 400 EVACUATOR, 400ML CAPACITY, Y-CONNECTING TUBE, 35" (88.9CM) STERILE
Common Device Name
SUCTION EVACUATOR
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington GA 30014
MDR Report Key10553065
Report Number1018233-2020-06028
Device Sequence Number571306
Product Code GCY
UDI-Device Identifier00801741049606
UDI-Public(01)00801741049606
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source health professional,other
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 01/14/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number0070800
Device Catalogue Number0070800
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/14/2020
Initial Date Received by Manufacturer 08/27/2020
Supplement Date Received by Manufacturer12/29/2020
Initial Report FDA Received Date09/18/2020
Supplement Report FDA Received Date01/14/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-