Model Number 7010
Medical Device Problem Code Break (1069)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 08/27/2020
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(6).
 
Event or Problem Description
It was reported that shaft break occurred.The target lesion was located in the left main artery.A 3.0mm x 12mm quantum maverick balloon catheter was advanced for dilatation.However, during procedure it was noted that the catheter was fractured.The device was simply pulled out and the procedure was completed with another of the same device.There were no patient complications nor injuries reported and the patient's status was stable.
 
Additional Manufacturer Narrative
(e1) - initial reporter facility name: (b)(6)hospital.Device evaluated by mfr: returned product consisted of a quantum maverick balloon catheter.The shaft, hypotube, tip and balloon were microscopically and visually examined.There were numerous kinks.There was a complete separation at 44.6cm distal of the strain relief.There was blood in the guidewire lumen.The balloon was tightly folded.Inspection of the remainder of the device presented no other damage or irregularities.
 
Event or Problem Description
It was reported that shaft break occurred.The target lesion was located in the left main artery.A 3.0mm x 12mm quantum maverick balloon catheter was advanced for dilatation.However, during procedure it was noted that the catheter was fractured.The device was simply pulled out and the procedure was completed with another of the same device.There were no patient complications nor injuries reported and the patient's status was stable.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
QUANTUM MAVERICK
Common Device Name
CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
MDR Report Key10568002
Report Number2134265-2020-12211
Device Sequence Number3145663
Product Code LOX
UDI-Device Identifier08714729392675
UDI-Public08714729392675
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
P860019
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,distri
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 10/30/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date12/31/2022
Device Model Number7010
Device Catalogue Number7010
Device Lot Number0024974489
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer09/15/2020
Initial Date Received by Manufacturer 08/28/2020
Supplement Date Received by Manufacturer10/13/2020
Initial Report FDA Received Date09/22/2020
Supplement Report FDA Received Date10/30/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age72 YR
Patient Weight62
-
-