Catalog Number 72200917
Medical Device Problem Code Positioning Problem (3009)
Health Effect - Clinical Code No Patient Involvement (2645)
Date of Event 09/02/2020
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that the fixation of spider arm was loose.No case involved.All available information has been disclosed.If additional information should become available, a supplemental report will be submitted accordingly.
 
Additional Manufacturer Narrative
The device, intended for use in treatment, was received for evaluation.There was a relationship found between the returned device and the reported incident.A visual inspection was performed on the product and a missing bolt on the clamp assembly was noted.A functional evaluation revealed that the device failed the weight test.The piston migration was at 2.2 inches, which is indicative of hydraulic fluid loss.The reported failure was confirmed and the root cause has been determined to be a seal failure.The device has been in service for over 5 years, thus any malfunction presented at this point in time would not be related to the manufacture of the product.A complaint history review concluded this was a repeat issue.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SPIDER FOR JAPANESE/ESCHMANN OR TABLE
Common Device Name
ACCESSORIES, OPERATING-ROOM, TABLE (KIT)
Manufacturer (Section D)
SMITH & NEPHEW, INC.
76 s. meridian ave.
oklahoma city OK 73107
MDR Report Key10589819
Report Number1643264-2020-01305
Device Sequence Number2822342
Product Code FWZ
UDI-Device Identifier00885554012910
UDI-Public885554012910
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 10/23/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Catalogue Number72200917
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 09/02/2020
Supplement Date Received by Manufacturer09/02/2020
Initial Report FDA Received Date09/25/2020
Supplement Report FDA Received Date10/23/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-