Model Number 133S-MX-11-T
Medical Device Problem Code Patient-Device Incompatibility (2682)
Health Effect - Clinical Codes Wound Dehiscence (1154); Foreign Body Sensation in Eye (1869); Unspecified Infection (1930)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Gt hold 9 28 concomitant of medical products: lot rh 217299-010, expiration 2021-12.Reference (b)(4) 16 x 20 cm perforated thick, date of therapy: (b)(6).A review of the device history record has been initiated.If any new, changed or corrected information is noted, a supplemental medwatch will be submitted.The events of "wound dehiscence, exposure, and infection" are physiological complications and analysis of the device generally does not assist allergan in determining a probable cause for these events.Further information from the reporter regarding event, product, or patient details has been requested.No additional information is available at this time.Reason for reoperation: "infection due to wound dehiscence and exposure".
 
Event or Problem Description
Hospital sales representative reported " revision is the result of removal of an infected tissue expander." healthcare provider also reported ¿wound dehiscence and exposure".Device has been explanted.This record is for the right side.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NATRELLE TE SMOOTH 133S-MX-11-T
Common Device Name
EXPANDER, SKIN, INFLATABLE
Manufacturer (Section D)
ALLERGAN (COSTA RICA)
900 parkway global park
zona franca
CS 
MDR Report Key10590605
Report Number9617229-2020-15402
Device Sequence Number2656076
Product Code LCJ
UDI-Device Identifier10888628044173
UDI-Public10888628044173
Combination Product (Y/N)N
Initial Reporter StateNJ
PMA/510(K) Number
P990074
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2020
Device Explanted Year2020
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 09/25/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date05/24/2024
Device Model Number133S-MX-11-T
Device Catalogue Number133S-MX-11-T
Device Lot Number3353236
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 08/28/2020
Initial Report FDA Received Date09/25/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
-
-