Catalog Number 8065752099
Device Problem No Flow (2991)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 09/01/2020
Event Type  malfunction  
Manufacturer Narrative
Investigation, including root cause analysis, is in progress.A supplemental mdr will be filed as necessary in accordance with 21 cfr 803.56 when additional reportable information becomes available.(b)(4).
 
Event Description
A customer reported that there was no flow during the procedure.Patient and procedure impact are unknown.
 
Manufacturer Narrative
Additional information provided in d.10, h.3, h.6 and h.10.A review of the device history record traceable to the reported lot number indicates that the product was processed and released according to the product¿s acceptance criteria.One wet intrepid plus fms was visually inspected and functionally tested.It was tested on a calibrated console and failed to prime, generated system message code 162.Leakage was observed from the aspiration tubing insertion to the cassette.Visual inspection indicated more solvent than typically applied around the tubing was present on the wall of the aspiration port of the cassette.The root cause of the customer's reported event was due to an assembly error during the internal manufacturing process.Due to most likely improperly applied solvent used during the assembly process, the aspiration tubing did not properly adhere to the cassette, which caused the priming failure.This complaint has been reviewed and it is determined that no further actions will be pursued at this time.In-process controls are established to ensure each final assembled cassette is verified that all required tests have been performed and all acceptance criteria are met prior to release.A complaint trend review for this lot also indicated this to be an isolated event for this finished goods lot.Quality assurance has reviewed this complaint and will continue to monitor data for evidence of adverse trending and take further action, as appropriate.The manufacturer internal reference number is: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INFINITI SURGICAL PROCEDURE PAK
Type of Device
GENERAL SURGERY TRAY (KIT)
Manufacturer (Section D)
ALCON RESEARCH, LLC - HOUSTON
9965 buffalo speedway
houston TX 77054
MDR Report Key10606676
MDR Text Key209547535
Report Number1644019-2020-00528
Device Sequence Number1
Product Code LRO
Combination Product (y/n)N
PMA/PMN Number
K880961
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional
Type of Report Initial,Followup
Report Date 12/23/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date12/31/2021
Device Catalogue Number8065752099
Device Lot Number02820Y
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/21/2020
Initial Date Manufacturer Received 09/15/2020
Initial Date FDA Received09/30/2020
Supplement Dates Manufacturer Received12/18/2020
Supplement Dates FDA Received12/23/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
CUSTOM-PAK SURGICAL PROCEDURE PACK
-
-