| Model Number |
371200 |
| Medical Device Problem Code |
Battery Problem (2885)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
09/08/2020
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
The device was not returned for analysis.The analysis is therefore only based on the returned device data as well as the inspection of the quality documents associated with the manufacture of this particular device.The manufacturing process for this device was re-investigated.All production steps had been performed accordingly.There was no sign of any inconsistency during the manufacturing.The returned device data were inspected, revealing that the warning message resulted from an unexpected battery behavior.However, based on the information available for analysis the root cause for this behavior was not determinable and can only be clarified by an analysis of the device itself.Biotronik has informed the health care professional about the unexpected battery behavior, who decides, based on the patients individual circumstances and medical judgment, if treatment is needed.Should further relevant information or the device itself become available, this investigation will be updated and you will be informed accordingly.
|
| |
|
Event or Problem Description
|
|
After an implantation period of approx.95 months, a message of a battery error was observed.
|
| |
|
Additional Manufacturer Narrative
|
|
Device was explanted and returned for analysis.The device was received for analysis.Prior to the analysis of the device, the quality documents accompanying the manufacturing process for this device were re-investigated and all production steps were performed accordingly.Particularly the final acceptance test proved the device functions to be as specified.Upon initial interrogation a warning message was triggered regarding the battery condition, confirming the clinical observation.The eri battery status was activated on (b)(6) 2021.The memory content of the device was inspected.The inspection revealed that the battery voltage decreased faster than expected.However, the current consumption was normal.The ability of the device to deliver therapies was verified.The anti-bradycardia pacing pulses proved to be normal and in amplitude and frequency as programmed in eri mode.There was no indication of a device malfunction.During subsequent analysis the device was opened and subjected to further investigation.The visual inspection of the inner assembly showed no anomalies.The measurement of the battery voltage confirmed an almost depleted battery.A thorough investigation of the electronic module did not show any abnormality.In particular, the current consumption was directly measured and proved to be normal and expected.The battery was sent to the manufacturer for further analysis.The manufacturing records of the battery were inspected, documenting that the battery parameters were within specification during the battery manufacturing.No anomalies were documented during the production process, associated with this battery.The battery was subjected to a visual and an electrical inspection as well as a microcalorimetry analysis.The visual inspection of the battery did not reveal any external signs of damage.The measurement of the battery voltage confirmed an almost depleted battery.The microcalorimetry analysis showed no anomalies.Next, the battery was opened for destructive analysis and the inner assembly was inspected.During analysis no internal electrical short was evident.However, the occurrence of a temporary short circuit that contributed to an increased internal self-depletion cannot be excluded.In summary, the root cause for the premature battery depletion could not be determined conclusively.Based on the analysis all therapy functions of the device were entirely available while the device was implanted and in service.
|
| |
|
Search Alerts/Recalls
|
|