Model Number 1650DE
Medical Device Problem Code Battery Problem (2885)
Health Effect - Clinical Codes No Consequences Or Impact To Patient (2199); No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/20/2020
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Additional products: heartware ventricular assist system: battery.Model #: 1650de / catalog #: 1650de / expiration date: 31-jul-2019 / serial or lot#: (b)(4), udi #: (b)(4), concomitant medical products/therapy dates? no.Mfg date: 11-jul-2018.Labeled for single use? no.(b)(4).Heartware ventricular assist system: battery.Model #: 1650de / catalog #: 1650de / expiration date: 31-jul-2019 / serial or lot#: (b)(4), udi #: (b)(4).Concomitant medical product/therapy dates? no.Mfg date: 11-jul-2018.Labeled for single use? no.(b)(4).Heartware ventricular assist system: battery.Model #: 1650de / catalog #: 1650de / expiration date: 31-jul-2019 / serial or lot#: (b)(4), udi #: (b)(4).Concomitant medical products/therapy dates? no.Mfg date: 12-jul-2018.Labeled for single use? no.(b)(4).Heartware ventricular assist system: battery.Model #: 1650de / catalog #: 1650de / expiration date: 30-sep-2019 / serial or lot#: (b)(4), udi #: (b)(4).Concomitant medical products/therapy dates? no.Mfg date: 15-sep-2018.Labeled for single use? no.(b)(4).Heartware ventricular assist system: battery.Model #: 1650de / catalog #: 1650de / expiration date: 30-sep-2019 / serial or lot#: (b)(4), udi #: (b)(4).Concomitant medical products/therapy dates? no.Mfg date: 15-sep-2018.Labeled for single use? no.(b)(4).Investigation of this event is pending, and a supplemental report will be sent upon its completion.If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
It was reported that the batteries exhibited power switching, intermittent beeping, and an inability to hold a charge.The batteries were exchanged.No patient complications have been reported as a result of this event.
 
Additional Manufacturer Narrative
Product event summary: six (6) batteries were returned for evaluation.Various analyses were conducted and reviewed in order to e valuate the performance of the devices in relation to the reported event.Failure analysis of the returned devices revealed that the batteries passed visual examination and functional testing.The reported event could not be duplicated during bench testing; the batteries did not experience any power switching events and were able to charge and discharge as expected while adequately providing power to a test controller.Controller log files were not available for analysis.As a result, the reported event could not be confirmed.There is no evidence the lubrication servicing has been performed on four batteries.A power source lubrication procedure had been performed on two batteries in accordance with the requirements under fsca cvg-18-q4-19 on 10-apr-2019.Applicable risk documentation and experience with events of similar circumstances were considered; a possible root cause of the reported premature power switching event can be attributed, but not limited, to a communication error and/or momentary disconnection due to temporary corrosion of the controller-port/power-source pins.Additional products: d4: serial or lot#: (b)(6) d9: yes, return date: 05-oct-2020 h3: yes h6: patient ime code(s): e2403 h6: imf code(s): f26 h6: fda method code(s): b01, b15 h6: fda results code(s): c19 h6: fda conclusion code(s): d14 d4: serial or lot#: (b)(6) d9: yes, return date: 05-oct-2020 h3: yes h6: patient ime code(s): e2403 h6: imf code(s): f26 h6: fda method code(s): b01, b15 h6: fda results code(s): c19 h6: fda conclusion code(s): d14 d4: serial or lot#: (b)(6) d9: yes, return date: 05-oct-2020 h3: yes h6: patient ime code(s): e2403 h6: imf code(s): f26 h6: fda method code(s): b01, b15 h6: fda results code(s): c19 h6: fda conclusion code(s): d14 d4: serial or lot#: (b)(6) d9: yes, return date: 05-oct-2020 h3: yes h6: patient ime code(s): e2403 h6: imf code(s): f26 h6: fda method code(s): b01, b15 h6: fda results code(s): c19 h6: fda conclusion code(s): d14 d4: serial or lot#: (b)(6) d9: yes, return date: 05-oct-2020 h3: yes h6: patient ime code(s): e2403 h6: imf code(s): f26 h6: fda method code(s): b01, b15 h6: fda results code(s): c19 h6: fda conclusion code(s): d14 investigation of this event is completed and the file will be closed.If new information is received, the file will be re-opened and a supplemental will be submitted.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HEARTWARE VENTRICULAR ASSIST SYSTEM - BATTERY
Common Device Name
VENTRICULAR (ASSIST) BYPASS
Manufacturer (Section D)
HEARTWARE, INC.
14400 nw 60th avenue
miami lakes FL 33014
MDR Report Key10613120
Report Number3007042319-2020-05925
Device Sequence Number14204304
Product Code DSQ
UDI-Device Identifier00888707002646
UDI-Public00888707002646
Combination Product (Y/N)N
Initial Reporter StateKS
Initial Reporter CountryUS
PMA/510(K) Number
P100047
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Nurse Practitioner
Type of Report Initial,Followup
Report Date (Section B) 11/24/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Expiration Date07/31/2019
Device Model Number1650DE
Device Catalogue Number1650DE
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/05/2020
Initial Date Received by Manufacturer 09/20/2020
Supplement Date Received by Manufacturer11/19/2020
Initial Report FDA Received Date10/01/2020
Supplement Report FDA Received Date11/24/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
1103 VAD; 1103 VAD
Patient Age46 YR
-
-