Model Number 71934993
Medical Device Problem Codes Adverse Event Without Identified Device or Use Problem (2993); Insufficient Device Problem Information (3190)
Health Effect - Clinical Codes Failure of Implant (1924); Injury (2348); Joint Dislocation (2374); Osteolysis (2377)
Date of Event 08/04/2020
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that, after a glenoid bone loss surgery, a revision had to be performed.The surgeon noted excessive resorption on the distal tibial allograft associated with the use of the round endobutton, as compared to the resorption when using screw fixation.The resorption was noted in the 2 year follow-up mri and confirmed during the revision surgery.The patient's outcome is unknown.All available information has been disclosed.If additional information should become available, a supplemental report will be submitted accordingly.
 
Additional Manufacturer Narrative
Report was inadvertently submitted under manufacturer number (b)(4) but the correct manufacturer number is (b)(4).
 
Additional Manufacturer Narrative
H10: h2: additional on a2, d8 and e1.H3, h6: a device deficiency was not identified, and the root cause of the reported event could not be determined since the device was not returned for evaluation.A review of device records showed there were no indications to suggest that the product did not meet manufacturing specifications upon release for distribution.A complaint history review found no similar reported events.The instructions for use were reviewed and found to include conditions of off label use and technique specifics, as well as precautions and warnings related to the use of the device.A risk management review found that the reported failure and/or harm was documented appropriately, and there were no indications to suggest the anticipated risk is not adequate.A clinical review states the provided report indicates resorption of the distal tibial allograft noted on an mri taken at two years post op.And two x-ray image dated one-month post primary and one seven months prior to revision shows four buttons used.Please refer to the instructions for use for recommendations on proper use of the device and potential troubleshooting methods to prevent future reoccurrence of the reported event.No containment or corrective actions are recommended at this time.If the product associated with this event is returned at a future date, this investigation will be reopened for evaluation.H11: h2: correction on d3 and h6.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RND ENDBTN POST SST W-SZ3/4 SUTURE LOOP
Common Device Name
SCREW, FIXATION, BONE
Manufacturer (Section D)
SMITH & NEPHEW, INC.
130 forbes blvd.
mansfield MA 02048
Manufacturer (Section G)
SMITH & NEPHEW, INC.
130 forbes blvd.
mansfield MA 02048
Manufacturer Contact
holly topping
7000 west william cannon drive
austin, TX 78735
5123913905
MDR Report Key10613353
Report Number1020279-2020-05012
Device Sequence Number1282580
Product Code HWC
UDI-Device Identifier00885556424544
UDI-Public00885556424544
Combination Product (Y/N)N
Initial Reporter CountryCA
PMA/510(K) Number
K183232
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2018
Device Explanted Year2020
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Other,Foreign,Health Professional,User Facility,Company Representative
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 02/13/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number71934993
Device Catalogue Number71934993
Device Lot Number17LM09599
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/02/2020
Supplement Date Received by Manufacturer09/02/2020
02/10/2023
Initial Report FDA Received Date10/01/2020
Supplement Report FDA Received Date12/07/2021
02/13/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention; Other;
Patient Age33 YR