SMITH & NEPHEW, INC. FULL RADIUS BLADE 5.5MM SER 3000; SAW, POWERED, AND ACCESSORIES Back to Search Results
Model Number 7206010
Medical Device Problem Code Break (1069)
Health Effect - Clinical Codes No Information (3190); No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 09/17/2020
Type of Reportable Event Serious Injury
Event or Problem Description
It was reported that during a shoulder scope surgery, when the surgeon started to use the blade, it dropped metal in the shoulder.Additionally, it was stated that the blade was being used on soft tissue, no bone work.Another blade was used to complete the surgery and to remove all metal pieces.No significant delay or other complications reported.All available information has been disclosed.If additional information should become available, a supplemental report will be submitted accordingly.
 
Additional Manufacturer Narrative
H3, h6: the reported device was received for evaluation.There was a relationship found between the device and the reported event.A visual evaluation showed the device was returned with a lidstock which shows the batch number of the complaint.The color scheme matches the print.The inner blade came separated from the outer blade.The outer blade and adapter show no visible deficiency.It is very clean and shiny through the cannula and outside.The inner blade shows dark discoloration and some scoring from friction on the distal end.The length of the inner blade has some discoloration.The blade edge shows sign of use but no definitive metal loss.A functional evaluation, using a reference control system, showed the blade functioned in all modes.No flakes were observed.A review of device records showed there were no indications to suggest that the product did not meet manufacturing specification upon release for distribution.A complaint history review found similar reported events.The instructions for use was reviewed and found to include conditions of off label use and technique specifics, as well as precautions and warnings related to the use of the device.A risk management review found that the reported failure and/or harm was documented appropriately, and there were no indications to suggest the anticipated risk is not adequate.No patient injuries or adverse consequences were reported.Since no patient injuries are being reported no further clinical/medical assessment is warranted at this time.The complaint was confirmed and the root cause was associated with unintended use of the device.Factors that may have contributed to the reported event include excessive side loading or insufficient irrigation during use.No containment or corrective actions are recommended at this time.H11: h2: corrected data on d8 and h6 (health effect - clinical code and impact code).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FULL RADIUS BLADE 5.5MM SER 3000
Common Device Name
SAW, POWERED, AND ACCESSORIES
Manufacturer (Section D)
SMITH & NEPHEW, INC.
130 forbes blvd.
mansfield MA 02048
Manufacturer (Section G)
SMITH & NEPHEW, INC.
130 forbes blvd.
mansfield MA 02048
Manufacturer Contact
holly topping
7000 west william cannon drive
austin, TX 78735
5123913905
MDR Report Key10656153
Report Number1219602-2020-01550
Device Sequence Number2704867
Product Code HAB
UDI-Device Identifier03596010440235
UDI-Public03596010440235
Combination Product (Y/N)N
Initial Reporter StateTN
Initial Reporter CountryUS
PMA/510(K) Number
EXEMPT
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source Health Professional,User Facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 11/03/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date07/31/2022
Device Model Number7206010
Device Catalogue Number7206010
Device Lot Number50854319
Was Device Available for Evaluation? Device Returned to Manufacturer
Is the Reporter a Health Professional? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 09/17/2020
Supplement Date Received by Manufacturer10/27/2023
Initial Report FDA Received Date10/09/2020
Supplement Report FDA Received Date11/03/2023
Was Device Evaluated by Manufacturer? (Y/N) Device Not Returned to Manufacturer
Date Device Manufactured01/31/2020
Is the Device Labeled for Single Use? (Y/N) Yes
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Usage of Device Initial
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient SexUnknown
-
-