Model Number 1074300-38
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Codes Cardiac Arrest (1762); Cardiac Enzyme Elevation (1838); Occlusion (1984); Ventricular Fibrillation (2130); Prolapse (2475)
Date of Event 09/16/2020
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
The device was not returned for evaluation.A review of the lot history record identified no manufacturing nonconformities issued to the reported lot that would have contributed to this event.The reported patient effect(s) of ventricular fibrillation and occlusion are listed in the xience xpedition everolimus eluting coronary stent systems instructions for use as a known patient effect(s) of coronary procedures.A conclusive cause for the reported patient effect(s), and the relationship to the product, if any, cannot be determined.However, the treatment appears to be related to the operational context of the procedure.There is no indication of a product quality issue with respect to manufacture, design or labeling.
 
Event or Problem Description
Patient id: (b)(6).It was reported that on (b)(6) 2020, the patient presented with in-stent restenosis with a chronic, total occlusion (100%) within the proximal right coronary artery (rca) lesion.Pre-dilatation was performed.Three 3.0x38mm xience xpedition stents were implanted and a 3.0x18mm xience xpedition stent was implanted without a device issue reported.Timi flow 3 and 0% residual stenosis was observed.Plaque shift had occurred within a xience stent and the side branch was lost.The side branch was attempted to be re-crossed unsuccessfully.The patient had gone into ventricular fibrillation, treated with cardioversion.During oct imaging, the patient went into cardiac arrest.The patients rhythm returned to normal sinus and the event resolved.Elevated cardiac enzymes were also observed without any treatment reported and without any new myocardial infarction (mi) diagnosed.Reportedly, the elevated enzymes were likely due to cardiac arrest along with loss of a side branch.The patient was kept overnight for observation.There was no device malfunction.No additional information was provided regarding this issue.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
XIENCE XPEDITION EVEROLIMUS ELUTING CORONARY STENT SYSTEM
Common Device Name
DRUG ELUTING CORONARY STENT DELIVERY SYSTEM
Manufacturer (Section D)
ABBOTT VASCULAR
26531 ynez rd.
temecula CA 92591 4628
MDR Report Key10656302
Report Number2024168-2020-08433
Device Sequence Number3552137
Product Code NIQ
UDI-Device Identifier08717648162381
UDI-Public08717648162381
Combination Product (Y/N)Y
Initial Reporter CountryCA
PMA/510(K) Number
P110019
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2020
Reporter Type Manufacturer
Report Source foreign,health professional,s
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 10/09/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Expiration Date08/07/2022
Device Model Number1074300-38
Device Catalogue Number1074300-38
Device Lot Number9080141
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 09/18/2020
Initial Report FDA Received Date10/09/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
3 IMPLANTED XIENCE XPEDITION STENTS
Outcome Attributed to Adverse Event Hospitalization; Required Intervention;
Patient Age73 YR
Patient Weight98
-
-