Reporter is a j&j employee.The device has been received, the investigation is in progress, no conclusion could be drawn at the time of filing this report.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|
|
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.H3, h4, h6: part 03.807.358, lot 1123: manufacturing site: oberdorf.Release to warehouse date: july 14, 2017.A manufacturing record evaluation was performed for the finished device lot number, and no non-conformances were identified.H3, h6: a service and repair evaluation was completed: the customer reported the device had failed in calibration.The repair technician reported the device failed low.Torque test low is the reason for repair.The item is not repairable per the inspection sheet.The item was forwarded to customer quality.The evaluation was confirmed.H3, h6: a product investigation was completed: upon visual inspection, no issues were observed with the returned device.No other issues were identified with the returned device.A functional test was performed on the returned device at service and repair evaluation.The highest torque of the device was measured to be not within the specification.Hence the device failed low during torque test.Based on the date of manufacture, the current and manufactured revision of drawings were reviewed.The complaint condition was confirmed.There is no indication that a design or manufacturing issue has caused the complaint condition and hence the root cause cannot be determined.The potential cause could be due to device maintenance.Based on the investigation findings, it has been determined that no corrective and/or preventative action is proposed.Additional monitoring for any potential safety signals will be conducted through complaint trending and other post market safety surveillance activities.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
|