As reported, the two (2) 4f 65cm 5 side holes (sh) universal flush (uf) tempo catheters were sheared off just below the last flush holes where it attached to the actual shaft of the catheter.There was no reported patient injury.The catheter was used in the normal manner.The devices were stored in the cath lab for less than a month.The devices were stored, handled, and prepped per the instructions for use (ifu).There was no difficulty experienced in prepping the devices.There were no anomalies noted prior to inserting the device into the patient.There was no damage noticed to the devices prior to opening the package.There was no difficulty removing the devices from the sterile packaging.There was no excess force used during the procedure.The procedure was completed using femoral access.There is no procedural cd/angiogram/ device images available.The devices will be returned for evaluation.
|
|
After further review of additional information received the following sections g4,g7,h2 and h6 have been updated accordingly.As reported, the two (2) 4f 65cm 5 side holes (sh) universal flush (uf) tempo catheters were sheared off just below the last flush holes where it attached to the actual shaft of the catheter.There was no reported patient injury.The catheter was used in the normal manner.The devices were stored in the cath lab for less than a month.The devices were stored, handled, and prepped per the instructions for use (ifu).There was no difficulty experienced in prepping the devices.There were no anomalies noted prior to inserting the device into the patient.There was no damage noticed to the devices prior to opening the package.There was no difficulty removing the devices from the sterile packaging.There was no excess force used during the procedure.The procedure was completed using femoral access.There is no procedural cd/angiogram/ device images available.The device was not returned for analysis as it was discarded.A product history record (phr) review of lot 17959811 revealed no anomalies or non-conformances during the manufacturing and inspection processes that can be associated with the reported event.The complaint reported by the customer as ¿brite tip/distal tip catheters - separated¿ was not confirmed.The returned unit does not present any separated condition.However, a kinked/bent condition was noticed at the distal tip.Exact cause of this condition could not be conclusively determined during the analysis.Without the return of the second device for analysis the reported event could not be confirmed and the exact root cause cannot be determined.Procedural/handling factors or vessel characteristics may have contributed to the reported events.According to the instructions for use (ifu), which is not intended as a mitigation of risk, ¿exercise care when removing guidewires from multiple-curve catheters.To prevent kinking of 5f (1.65 mm) and smaller angiographic catheters; straighten the pigtail catheter tip only with a diagnostic guidewire or, if applicable, with a tip straightener.Do not straighten by hand.Use a guidewire when introducing the catheter through the catheter sheath introducer (csi) and into the left ventricle.Treat all 4f catheters and smaller french sizes with ultimate care.The performance of these products may be impaired if not properly and cautiously handled during unpacking and preparation.Procedures requiring percutaneous catheter introduction should not be attempted by physicians unfamiliar with the possible complications.Complications may occur at any time during or after the procedure.¿ neither the phr review nor the product analysis suggest that the observed damages could be related to the manufacturing process of the unit.Therefore, no corrective or preventive actions will be taken at this time.This is one of two devices involved in the reported event.The reporting reference number of the related device is 9616099-2020-03998.
|