| Catalog Number |
701M6540 |
| Medical Device Problem Code |
Biocompatibility (2886)
|
| Health Effect - Clinical Codes |
Hypersensitivity/Allergic reaction (1907); Rash (2033); Swelling (2091); Eczema (4547); Swelling/ Edema (4577)
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
Without a product return, no product evaluation is able to be conducted.The lot number is unknown; therefore the device history records are unable to be reviewed.Current information is insufficient to permit a valid conclusion about the cause of this event.If additional information is obtained that adds value to the relevant content of this report and/or a conclusion can be drawn, a follow-up report will be sent.Reference report numbers 3012447612-2020-00629 thru 3012447612-2020-00642.
|
| |
|
Event or Problem Description
|
|
It was reported that the patient is having a possible allergic reaction to some spinal implants.The installed implants include an epic construct and a breckenridge cage.The patient is allergic to nickel and may be sensitive to cobalt chrome.Allergy tests are on-going and a plan for care has not yet been made.This is report seven of 14 for this event.
|
| |
|
Additional Manufacturer Narrative
|
|
Information added to d8 and h6: component, investigation type, findings, and conclusions.This follow-up report is being submitted to relay additional information.Summary: the complaint is unrefuted for the vitality construct causing an allergic reaction.Medical records were not provided for review.Device evaluation: product was not returned as it remains implanted.A device evaluation could not be performed.Potential cause: root cause was unable to be determined with the available information.Dhr review and related actions the lot numbers were not provided, so the dhr review could not be performed.Device use these devices are used for treatment.A follow-up report will be submitted if new information is received that changes the information provided in this report.
|
| |
|
Event or Problem Description
|
|
It was reported that the patient is having a possible allergic reaction to some spinal implants.The installed implants include an epic construct and a breckenridge cage.The patient is allergic to nickel and may be sensitive to cobalt chrome.Allergy tests are on-going and a plan for care has not yet been made.This is report seven of 14 for this event.
|
| |
|
Event or Problem Description
|
|
It was reported that the patient is having a possible allergic reaction to some spinal implants.The installed implants include a pedicle screw construct.The patient is allergic to nickel and may be sensitive to cobalt chrome.Allergy tests are on-going and a plan for care has not yet been made.This is report seven of 14 for this event.
|
| |
|
Additional Manufacturer Narrative
|
|
Corrected information in b5.A follow-up report will be submitted if new information is received that changes the information provided in this report.
|
| |
|
Additional Manufacturer Narrative
|
|
H6: additional patient code: 4421.Corrections in b5, b6, b7, d4: lot & udi numbers, h6: clinical and impact codes.Additional information in a2, a4, a5, a6, d6b, and h4.If additional information is obtained that adds value to the relevant content of this report, a follow-up report will be sent.
|
| |
|
Event or Problem Description
|
|
It was reported that the patient is having a possible allergic reaction to some spinal implants, including tingling, swelling, and eczema.The installed implants include a pedicle screw construct.The patient is allergic to nickel and may be sensitive to cobalt chrome.Allergy tests are on-going.This is report 11 of 14 for this event.New information received: a revision surgery was performed to remove the posterior fusion construct.
|
| |
|
Additional Manufacturer Narrative
|
|
H6: additional method code: 4110 additional information in h6: investigation type, findings, and conclusions.Device evaluation: the device was not returned and no photos were provided, so an evaluation is unable to be performed.Root cause: a definitive root cause cannot be determined with the information provided.This event could possibly be attributed to unknown patient or surgical factors.Dhr review: the dhr was reviewed.There are no indications of manufacturing issues which would have contributed to this event and the device was likely conforming when it left highridge medical¿s control.Device usage: this device is used for treatment.If additional information is obtained that adds value to the relevant content of this report, a follow-up report will be sent.
|
| |
|
Event or Problem Description
|
|
It was reported that the patient is having a possible allergic reaction to some spinal implants, including tingling, swelling, and eczema.The installed implants include a pedicle screw construct.The patient is allergic to nickel and may be sensitive to cobalt chrome.Allergy tests are on-going.This is report 11 of 14 for this event.New information received: a revision surgery was performed to remove the posterior fusion construct.
|
| |
|