• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION SUPER SHEATH INTRODUCER SHEATH; INTRODUCER, CATHETER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION SUPER SHEATH INTRODUCER SHEATH; INTRODUCER, CATHETER Back to Search Results
Model Number 28211
Medical Device Problem Code Unsealed Device Packaging (1444)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 09/19/2020
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
(b)(6).
 
Event or Problem Description
It was reported that device contamination occurred.A 10frx11cm super sheath introducer sheath was selected for use.Upon unpacking, it was noted that the primary packaging was open.The secondary packaging was sealed but the device was not used as it has lost its sterility.The procedure was completed with a different device.There were no patient complications were reported.
 
Event or Problem Description
It was reported that device contamination occurred.A 10frx11cm super sheath introducer sheath was selected for use.Upon unpacking, it was noted that the primary packaging was open.The secondary packaging was sealed but the device was not used as it has lost its sterility.The procedure was completed with a different device.There were no patient complications were reported.
 
Additional Manufacturer Narrative
E1: initial reporter facility name (b)(6).E1: initial reporter address 1- (b)(6).Device evaluated by manufacturer: the device was not returned for analysis.The actual item was not returned, but photos were provided.From an investigation of the provided photo, it was confirmed that the sealed part on the opposite side of the opening mouth of the sterile bag was open.An adhesive mark was observed on the part of the sterile bag where the seal was open.
 
Event or Problem Description
It was reported that device contamination occurred.A 10frx11cm super sheath introducer sheath was selected for use.Upon unpacking, it was noted that the primary packaging was open.The secondary packaging was sealed but the device was not used as it has lost its sterility.The procedure was completed with a different device.There were no patient complications were reported.
 
Additional Manufacturer Narrative
E1: initial reporter facility name - (b)(6).E1: initial reporter address 1- (b)(6).Device evaluated by manufacturer: the device was returned for analysis.One set of packaging with a sheath in it was returned.Actual returned product was investigated, and it was confirmed that the central part of the seal part on the opposite side of the opening mouth of the sterile bag was open.Seal marks were found on the part where the seal of the sterile bag was peeled off.It was also confirmed that the part where the seal remains was firmly welded.Welding peel strength of the part where the seal remains was measured, and it was confirmed that it was above the standard value.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SUPER SHEATH INTRODUCER SHEATH
Common Device Name
INTRODUCER, CATHETER
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
MDR Report Key10749317
Report Number2134265-2020-14857
Device Sequence Number3060539
Product Code DYB
UDI-Device Identifier14543527201916
UDI-Public14543527201916
Combination Product (Y/N)N
Initial Reporter CountryMX
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 01/22/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/31/2022
Device Model Number28211
Device Catalogue Number28211
Device Lot Number19B07B1
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/23/2020
Initial Date Received by Manufacturer 10/07/2020
Supplement Date Received by Manufacturer11/16/2020
01/11/2021
Initial Report FDA Received Date10/28/2020
Supplement Report FDA Received Date11/30/2020
01/22/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-