Model Number M00576550
Medical Device Problem Codes Material Deformation (2976); Positioning Problem (3009)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 10/08/2020
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).The complainant indicated that the device was disposed and will not be returned for evaluation; therefore, a failure analysis of the complaint device could not be completed.If any further relevant information is identified, a supplemental medwatch will be filed.
 
Event or Problem Description
It was reported to boston scientific corporation on (b)(6) 2020 that an ultraflex tracheobronchial covered distal release stent was to be implanted in the lung to treat a malignant stricture during a bronchoscopy with stent placement procedure performed on (b)(6) 2020.Reportedly, the patient's anatomy was moderately tortuous and was not dilated prior to stent placement.According to the complainant, during the procedure, the delivery catheter kinked when deploying the stent.Reportedly, as a result, the stent moved proximal and was in an incorrect location.The stent was attempted to be adjusted with forceps but was unsuccessful.Reportedly, the stent was removed with rat-tooth forceps and the procedure was completed with another ultraflex tracheobronchial stent.There were no patient complications as a result of this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ULTRAFLEX TRACHEOBRONCHIAL
Common Device Name
PROSTHESIS, TRACHEAL, EXPANDABLE
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
300 boston scientific way
marlborough MA 01752
MDR Report Key10774764
Report Number3005099803-2020-05070
Device Sequence Number3884251
Product Code JCT
UDI-Device Identifier08714729842354
UDI-Public08714729842354
Combination Product (Y/N)N
Initial Reporter StateMO
Initial Reporter CountryUS
PMA/510(K) Number
K141584
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 11/02/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date07/10/2022
Device Model NumberM00576550
Device Catalogue Number7655
Device Lot Number0025696542
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 10/12/2020
Initial Report FDA Received Date11/02/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
-
-