U.S. Department of Health and Human Services

MAUDE Adverse Event Report: COOK INC CAPTURA HELICAL STONE EXTRACTOR; FFL DISLODGER, STONE, BASKET, URETERAL, METAL

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

COOK INC CAPTURA HELICAL STONE EXTRACTOR; FFL DISLODGER, STONE, BASKET, URETERAL, METAL Back to Search Results
Model Number G32727
Medical Device Problem Code Unsealed Device Packaging (1444)
Health Effect - Clinical Code No Patient Involvement (2645)
Date of Event 10/21/2020
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Customer name and address: phone: (b)(6).Occupation: quality specialist.Pma/510(k) number: exempt this report includes information known at this time.A follow-up report will be submitted should additional relevant information become available.
 
Event or Problem Description
As reported, during inspection by a distributor, the packaging of a captura helical stone extractor was found unsealed.The device did not make contact with a patient and was not used for any procedure.
 
Event or Problem Description
No new patient or event information since the last report was submitted.
 
Additional Manufacturer Narrative
Blank fields on this form indicate the information is unknown, unchanged, or unavailable.Event summary: cook was informed of an incident involving a captura helical stone.The device reportedly was found to have a pouch that was not sealed.The issue was noted at a distributor and was not associated with any procedure or patient.Investigation ¿ evaluation: a visual inspection of the returned device was conducted.A document-based investigation was also performed including a review of complaint history, device history record, manufacturing instructions, specifications, and quality control data.Visual examination confirmed the device was received in unused condition.The bottom straight seal was open.The seal to the right of the notch was intact but wrinkled.The seal to the left of the notch was severely wrinkled and open.The package showed no signs of having been sealed on the left side.The white tyvek on the back was wrinkled, correlating with the clear poly wrinkle damage on the front of the package.Black debris was noted at the bottom of the package.The package and device sterility was compromised.A review of the device history record (dhr) found no non-conformances related to the reported failure mode.Because there are no related non-conformances, adequate inspection activities have been established, there is objective evidence that the dhr was fully executed, and no other related complaints from the lot have been received from the field, it was concluded that there is no evidence that additional nonconforming product exists in house or in field.A review of complaint history records shows no other complaints associated with the complaint device lot.Based on the information available, cook has concluded that the cause of this issue was a manufacturing issue that the seal was not properly formed, and the defect was not caught upon subsequent inspection.The sealing operator was made aware of the issue and retrained in the sealing procedure.The quality inspector was no longer employed at cook and could not be retrained.Per the quality engineering risk assessment, no further action is warranted.Cook medical will continue to monitor this device via the complaints database for similar complaints.This report is required by the fda under 21 cfr part 803.This report is based on unconfirmed information submitted by others.Neither the submission of this report nor any statement made in it is intended to be an admission that any cook device is defective or malfunctioned; that a death or serious injury occurred; or that any cook device caused or contributed to; or is likely to cause or contribute to a death or serious injury if a malfunction occurred.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CAPTURA HELICAL STONE EXTRACTOR
Common Device Name
FFL DISLODGER, STONE, BASKET, URETERAL, METAL
Manufacturer (Section D)
COOK INC
750 daniels way
bloomington IN 47404
MDR Report Key10789396
Report Number1820334-2020-02013
Device Sequence Number2917792
Product Code FFL
UDI-Device Identifier00827002327276
UDI-Public(01)00827002327276(17)230312(10)13047350
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source distributor,foreign,other
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 12/15/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device No Information
Device Expiration Date03/12/2023
Device Model NumberG32727
Device Catalogue NumberCE-432115
Device Lot Number13047350
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/12/2020
Initial Date Received by Manufacturer 10/22/2020
Supplement Date Received by Manufacturer12/07/2020
Initial Report FDA Received Date11/04/2020
Supplement Report FDA Received Date12/15/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No