• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: AESCULAP AG AS VEGA PS TIBIAL PLATEAU CEMENTED T0; KNEE ENDOPROSTHETICS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

AESCULAP AG AS VEGA PS TIBIAL PLATEAU CEMENTED T0; KNEE ENDOPROSTHETICS Back to Search Results
Model Number NX049Z
Medical Device Problem Code Loosening of Implant Not Related to Bone-Ingrowth (4002)
Health Effect - Clinical Codes Pain (1994); Ambulation or Postural Difficulties (2544)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Reference code: nx049z).Device name as vega ps tibial plateau; cemented t0; serial number: n/a; batch number: 51922841 udi device identifier: (b)(4); udi production identifier: (b)(4); basic udi: (b)(4).Unit of use udi: (b)(4).Manufacturing date 2013-02-28.Ref.Code: device name: batch#: nn261; as tibial obturator d12mm; 52061806 nx008z); as vega ps femoral comp.Cemented; f3l 51637843 nx042); patella 3-pegs p2; 52008894 nx101); vega ps gliding surface t0/0+ 12mm; 51906667.Investigation: no product at hand.Therefore, an investigation at the device is not possible.Pictorial documentation: there are no pictures available.Batch history review: the device quality and manufacturing history records (dhr) have been checked for all available lot numbers and the products found to be according to our specification valid at the time of production.There are 4 similar complaints against the same lot number: 51922841.(all registered as leading components).There are 3 similar complaints against the same lot number: 52061806.(all registered as involved components).There are 2 similar complaints against the same lot number: 51637843.(1 registered as leading component, 1 registered as involved component).Explanation and rationale: in the light of the little information received and due the circumstance that we did not received the complained devices it is not possible to determine a root cause for the mentioned failure.Corrective action: for this topic (loosening) a product safety case (psc) was initiated.
 
Event or Problem Description
It was reported that there was an issue with as vega knee.It was reported that as a result of having the product implanted, the patient has experienced knee pain, difficulty walking, and loosening and instability of the device.The primary procedure occurred on (b)(6) 2015, and the revision was performed on (b)(6) 2018.All available information has been provided at this time, if additional information becomes available the complaint will be updated accordingly.Involved components: nn261z (tibial obturator d12mm, l7mm); nx049z (ps tibia cemented t0); nx008z (ps femur cemented f3 lt); nx042 (universal patella p2); nx101 (ps pe insert t0/t0+, 12mm).The cement used was unspecified.The adverse event / malfunction is filed under reference (b)(4).Associated medwatches: 2916714-2020-00490; 2916714-2020-00492; 2916714-2020-00493; 2916714-2020-00494.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AS VEGA PS TIBIAL PLATEAU CEMENTED T0
Common Device Name
KNEE ENDOPROSTHETICS
Manufacturer (Section D)
AESCULAP AG
po box 40
tuttlingen, 78501
GM  78501
MDR Report Key10801740
Report Number2916714-2020-00491
Device Sequence Number17058118
Product Code HRY
UDI-Device Identifier04046963810337
UDI-Public4046963810337
Combination Product (Y/N)N
Initial Reporter StateCA
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Importer
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 11/06/2020
Report Date (Section F) 11/06/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/01/2023
Device Model NumberNX049Z
Device Catalogue NumberNX049Z
Device Lot Number51922841
Was Device Available for Evaluation? No
Was the Report Sent to FDA? Yes
Distributor Facility Aware Date01/09/2019
Event Location Hospital
Initial Date Received by Manufacturer Not provided
Initial Report FDA Received Date11/06/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Date Report Sent to FDA11/06/2020
-
-