Model Number NX042
Medical Device Problem Code Loosening of Implant Not Related to Bone-Ingrowth (4002)
Health Effect - Clinical Codes Pain (1994); Synovitis (2094); Ambulation or Postural Difficulties (2544)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Reference code: nx009z.Device name: as vega ps femoral comp.Cemented f4n l.Serial number: n/a.Batch number: 51942882.Udi device identifier (b)(4).Udi production identifier: (b)(4).Basic udi-di: n/a.Unit of use udi-di (b)(4).Manufacturing date: 2013-06-14.Ref.Code device name: batch.Nx042 patella 3-pegs p2 51944942.Nx049z as vega ps tibial plateau cemented t0 51922841.Nx100 vega ps gliding surface t0/0+ 10mm 51936235.Nn260p plug f/tibial plateau 51950754.Investigation: no product at hand.Therefore an investigation at the device is not possible.Pictorial documentation: there are no pictures available.Batch history review: the device quality and manufacturing history records (dhr) have been checked for all available lot numbers and the products found to be according to our specification valid at the time of production.There are 4 similar complaints against the same lot number 51922841.(3 registered as leading component; 1 registered as involved components) there are 3 similar complaints against the same lot number 51950754 ( all registered as involved components).Explanation and rationale: in the light of the little information received and due the circumstance that we did not received the complained devices it is not possible to determine a root cause for the mentioned failure.Corrective action: for this topic (loosening) a product safety case (psc) was initiated.
 
Event or Problem Description
It was reported that there was an issue with as vega knee, left side.It was reported that as a result of having the product implanted, the patient has experienced knee pain and swelling; and normal daily activities were restricted due to the pain.The primary procedure occurred on (b)(6) 2013, and the revision was performed on (b)(6) 2016.Intraoperative findings showed loosening of the femoral component, metallosis and debris in the knee joint, and reactive synovitis.All available information has been provided at this time, if additional information becomes available the complaint will be updated accordingly.Involved components: nx009z (ps femur cemented f4n lt).Nx042 (universal patella p2).Nx049z (ps tibia cemented t0).Nx100 (ps pe insert t0/t0+, 10mm).Nn260p (peek plug f/ tibia).The cement used was unspecified.The adverse event / malfunction is filed under reference (b)(4).Associated medwatches: 2916714-2020-00506, 2916714-2020-00508, 2916714-2020-00509, 2916714-2020-00510.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PATELLA 3-PEGS P2
Common Device Name
KNEE ENDOPROSTHETICS
Manufacturer (Section D)
AESCULAP AG
po box 40
tuttlingen, 78501
GM  78501
MDR Report Key10802522
Report Number2916714-2020-00507
Device Sequence Number11676747
Product Code HRY
UDI-Device Identifier04046963810283
UDI-Public4046963810283
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Importer
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 11/06/2020
Report Date (Section F) 11/06/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date04/01/2018
Device Model NumberNX042
Device Catalogue NumberNX042
Device Lot Number51944942
Was Device Available for Evaluation? No
Was the Report Sent to FDA? Yes
Distributor Facility Aware Date02/15/2019
Event Location Hospital
Initial Date Received by Manufacturer Not provided
Initial Report FDA Received Date11/06/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Date Report Sent to FDA11/06/2020
-
-