• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: AESCULAP AG VEGA PS GLIDING SURFACE T0/0+ 10MM; KNEE ENDOPROSTHETICS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

AESCULAP AG VEGA PS GLIDING SURFACE T0/0+ 10MM; KNEE ENDOPROSTHETICS Back to Search Results
Model Number NX100
Medical Device Problem Code Loosening of Implant Not Related to Bone-Ingrowth (4002)
Health Effect - Clinical Codes Pain (1994); Synovitis (2094); Ambulation or Postural Difficulties (2544)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Reference code: (b)(4).Device name as vega ps femoral comp.Cemented f4n l.Serial number: n/a.Batch number: 51942882.Udi device identifier: (b)(4).Udi production identifier: (b)(4).Basic udi: (b)(4).Unit of use udi: (b)(4).Manufacturing date: 2013-06-14.Ref.Code: device name: batch#: b)(4); patella 3-pegs p2; 51944942.(b)(4); as vega ps tibial plateau cemented t0; 51922841.(b)(4); vega ps gliding surface t0/0+ 10mm; 51936235.(b)(4); plug f/tibial plateau; 51950754.Investigation: no product at hand.Therefore, an investigation at the device is not possible.Pictorial documentation: there are no pictures available.Batch history review: the device quality and manufacturing history records (dhr) have been checked for all available lot numbers, and the products found to be according to our specification valid at the time of production.There are 4 similar complaints against the same lot number: 51922841.(3 registered as leading component; 1 registered as involved components) there are 3 similar complaints against the same lot number: 51950754 ( all registered as involved components).Explanation and rationale: in the light of the little information received, and due the circumstance that we did not received the complained devices it is not possible to determine a root cause for the mentioned failure.Corrective action: for this topic (loosening) a product safety case (psc) was initiated.
 
Event or Problem Description
It was reported that there was an issue with as vega knee, left side.It was reported that as a result of having the product implanted, the patient has experienced knee pain and swelling, and normal daily activities were restricted due to the pain.The primary procedure occurred on (b)(6) 2013, and the revision was performed on (b)(6) 2016.Intraoperative findings showed loosening of the femoral component, metallosis, and debris in the knee joint, and reactive synovitis.All available information has been provided at this time, if additional information becomes available the complaint will be updated accordingly.Involved components: nx009z (ps femur cemented f4n lt); nx042 (universal patella p2); nx049z (ps tibia cemented t0); nx100 (ps pe insert t0/t0+, 10mm); nn260p (peek plug f/ tibia).The cement used was unspecified.The adverse event / malfunction is filed under reference (b)(4).Associated medwatches: 2916714-2020-00506; 2916714-2020-00507; 2916714-2020-00508; 2916714-2020-00510.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
VEGA PS GLIDING SURFACE T0/0+ 10MM
Common Device Name
KNEE ENDOPROSTHETICS
Manufacturer (Section D)
AESCULAP AG
po box 40
tuttlingen, 78501
GM  78501
MDR Report Key10802532
Report Number2916714-2020-00509
Device Sequence Number19776388
Product Code HRY
UDI-Device Identifier04046963810702
UDI-Public4046963810702
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Importer
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date (Section B) 11/06/2020
Report Date (Section F) 11/06/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date03/01/2018
Device Model NumberNX100
Device Catalogue NumberNX100
Device Lot Number51936235
Was Device Available for Evaluation? No
Was the Report Sent to FDA? Yes
Distributor Facility Aware Date02/15/2019
Event Location Hospital
Initial Date Received by Manufacturer Not provided
Initial Report FDA Received Date11/06/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Date Report Sent to FDA11/06/2020
-
-