Model Number 7211
Medical Device Problem Code Material Deformation (2976)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 08/20/2020
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Initial reporter facility name: (b)(6).Device evaluation by mfr: returned product consisted of an nc emerge balloon catheter.The shaft, hypotube, tip and balloon were microscopically and visually examined.There were numerous kinks.There was a complete separation at 25.9cm distal of the strain relief.There was blood in the guidewire lumen.The balloon was tightly folded.Inspection of the remainder of the device presented no other damage or irregularities.
 
Event or Problem Description
Reportable based on device analysis completed on 27oct2020.It was reported that shaft kink occurred.The target lesion was located in the left main artery.A 3.00mm x 8mm nc emerge balloon catheter was advanced for use.However, during procedure, the delivery shaft was kinked at about 15 cm from the hub.The device was completely removed and the procedure was completed with another of the same device.No patient complications were reported and the patient's status was stable.However, device analysis revealed a shaft break.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NC EMERGE
Common Device Name
CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
MDR Report Key10845135
Report Number2134265-2020-15669
Device Sequence Number3629967
Product Code LOX
UDI-Device Identifier08714729846260
UDI-Public08714729846260
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K141236
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,distri
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 11/16/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date01/30/2022
Device Model Number7211
Device Catalogue Number7211
Device Lot Number0025134690
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/02/2020
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 10/27/2020
Initial Report FDA Received Date11/16/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age66 YR
Patient Weight66
-
-