| Catalog Number |
0010215 |
| Medical Device Problem Codes |
Defective Device (2588); Insufficient Device Problem Information (3190); Migration (4003)
|
| Health Effect - Clinical Codes |
Adhesion(s) (1695); Pain (1994); Hernia (2240); Injury (2348); Disability (2371)
|
| Date of Event |
11/20/2019
|
|
Type of Reportable Event
|
Serious Injury
|
|
Additional Manufacturer Narrative
|
|
No conclusions can be made.The patient's attorney alleges "past, present, and future damages, including but not limited to, mental and physical pain and suffering for severe and permanent personal injuries sustained by the patient"; however, no details have been provided.No lot number has been provided; therefore, a review of the manufacturing records is not possible.Should additional information be provided, a supplemental emdr will be submitted.
|
| |
|
Event or Problem Description
|
|
Attorney alleges that the patient underwent surgery for the implant of an unspecified bard/davol ventrio on (b)(6) 2018.As reported, the patient is making a claim for an adverse patient outcome against ventrio.Attorney alleges general allegations for "past, present, and future damages, including but not limited to, mental and physical pain and suffering for severe and permanent personal injuries sustained by the patient." it is also alleged that the patient experienced emotional distress and the device was defective.
|
| |
|
Additional Manufacturer Narrative
|
|
No conclusions can be made.The patient's attorney alleges "past, present, and future damages, including but not limited to, mental and physical pain and suffering for severe and permanent personal injuries sustained by the patient"; however, no details have been provided.No lot number has been provided; therefore, a review of the manufacturing records is not possible.Addendum: this supplemental emdr is submitted to document additional information provided.Root cause is inconclusive, no conclusion can be made as to the extent to which the implant may have caused or contributed to the patient's postoperative course.Note, the manufacturing date (15-oct-2017) is considered to be a best estimate.Updated fields: a2, b2, b3 (date of event), b4, b5, b7, d3, d4, d.6b (date of explant), g3, g6, h2, h4, h6, h10.Note: section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : not returned.
|
| |
|
Event or Problem Description
|
|
Attorney alleges that the patient underwent surgery for the implant of an unspecified bard/davol ventrio on (b)(6) 2018.As reported, the patient is making a claim for an adverse patient outcome against ventrio.Attorney alleges general allegations for "past, present, and future damages, including but not limited to, mental and physical pain and suffering for severe and permanent personal injuries sustained by the patient." it is also alleged that the patient experienced emotional distress and the device was defective.Addendum per additional information provided: (b)(6) 2018 ¿ patient was diagnosed with recurrent ventral incisional hernia thereby underwent open repair with implant of ventrio mesh.Per operative notes, ¿two midline fascial defects were encountered.The hernia and sac was reduced and two fascial defect was combined into a single defect and ventrio mesh was placed over the defect and sutured.¿ (b)(6) 2019 - patient was diagnosed with recurrent incarcerated incisional hernia (x2) thereby underwent open repair with removal of ventrio mesh and implant of synthetic mesh.Per operative notes, ¿hernia in the midline and left lower quadrant was noted.Prior mesh was seen pulled away from the abdominal wall.The mesh was excised completely and adhesions were lysed.The defect was closed with sutures and synthetic mesh was placed.¿.
|
| |
|