(b)(6) 2020: a 69 year-old male patient received injections of carbocain (mepivacaine), depo-medrol(methylprednisolone) and artz dispo to right shoulder for periarthritis scapulohumeralis at 3:45 pm.At 4:05 pm, he had binocular hyperemia and eyelid swelling, facial flush, redness and itching in the palms of both hands, itching on the abdomen.At 4:10 pm, his blood pressure was 137/94 and pulse was 107.He stated flushing and fast heartbeat.His intravenous route was secured with 250 ml physio140 (glucose-added ringer's solution) and 20 ml lemigen (glycyrrhizinate).His face was iced with a wet towel.At 4:20 pm, his blood pressure was 132/94 and pulse was 62.He had uncomfortable in the throat and mild suffocation.At 4:30 pm, he took one tablet of 30 mg oxatowa (oxatomide) and 10mg takecab (vonoprazan).At 4:50 pm, his blood pressure was 140/104 and pulse was 69.He developed complicated premature constractions.He felt chill slightly and shivered with cold.His body temperature was 36.2 degrees.At 5:23 pm, his binocular hyperemia, facial flush were improving.His itching in the palms of both hands and on the abdomen were improved.He was prescribed 5mg allelock(olopatadine).He went to home by walk.His symptoms were improved mostly before sleeping.(b)(6) 2020: he recovered when he got up.
|