COOK ENDOSCOPY ACUSNARE POLYPECTOMY SNARE; FDI, SNARE, FLEXIBLE Back to Search Results
Model Number G22647
Medical Device Problem Code Retraction Problem (1536)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 11/18/2020
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Pma/510(k) # k191048.Investigation evaluation: a product evaluation was not performed in response to this report because the product said to be involved was not provided to cook for evaluation.The report could not be confirmed.The device history record for the lot number said to be involved was reviewed.The device history record contains non-conformances that could potentially be related to this report.The device goes through different inspections prior to leaving the facility.These inspections would have removed any nonconforming devices prior to distribution.A discrepancy or anomaly was not observed with the product that was released for distribution.Investigation conclusion: we could not conduct a complete investigation because the product said to be involved was not returned for evaluation.A definitive cause for the reported observation could not be determined.The instructions for use direct the user to: "fully retract and extend snare to confirm smooth operation of device." damage to the product can occur if the device experiences excessive pressure during use.Prior to distribution, all acusnare polypectomy snares are subjected to a visual inspection.A review of the device history record confirmed that the lot said to be involved met all manufacturing requirements prior to shipment.Corrective action: corrective action is not warranted at this time based on the quality engineering risk assessment.Quality assurance will continue to monitor for complaint trends and reassess the risk assessment results as post market feedback continues to become available.
 
Event or Problem Description
During an endoscopic polypectomy, the physician used a cook acusnare polypectomy snare.The housing over the snare wire, near the handle, was buckling or wrinkling.It was not closing effectively.Then it would snap shut.The procedure was successfully completed with a different crescent snare.A section of the device did not remain inside the patient¿s body.The patient did not require any additional procedures due to this occurrence.According to the initial reporter, the patient did not experience any adverse effects due to this occurrence.
 
Additional Manufacturer Narrative
Investigation evaluation: the product said to be involved was returned in a plastic pouch with no lot number.Our laboratory evaluation of the product said to be involved confirmed the report.During a visual evaluation of the returned device, the snare head was retracted.At the distal end of the handle, the catheter is collapsing due to the force of retracting the snare head and is severely kinked.During a functional test, the handle of the device was manipulated, the snare head would not advance and retract as intended.There was a lot of resistance, and occasionally the snare head would get stuck halfway during retraction.The resistance caused further damage to the catheter by the distal end of the handle.The distal end of the snare was viewed under magnification and appears to be within specification.A laboratory meeting was held with manufacturing and engineering; no anomalies were detected with the device construction.The device history record for the lot number said to be involved was reviewed.The device history record contains non-conformances that could potentially be related to this report.The device goes through different inspections prior to leaving the facility.These inspections would have removed any nonconforming devices prior to distribution.A discrepancy or anomaly was not observed with the product that was released for distribution.Investigation conclusion: a definitive cause for this observation could not be determined because the actual use conditions could not be duplicated in the laboratory setting.Due to a variety of clinical conditions such as patient anatomy, endoscope position or progression of disease state, we could not reproduce the actual conditions of product usage during our laboratory analysis.This limits our ability to conclusively determine a cause.The instructions for use direct the user to: "fully retract and extend snare to confirm smooth operation of device." damage to the product can occur if the device experiences excessive pressure during use.Prior to distribution, all acusnare polypectomy snares are subjected to a visual inspection.A review of the device history record confirmed that the lot said to be involved met all manufacturing requirements prior to shipment.Corrective action: corrective action is not warranted at this time based on the quality engineering risk assessment.Quality assurance will continue to monitor for complaint trends and reassess the risk assessment results as post market feedback continues to become available.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ACUSNARE POLYPECTOMY SNARE
Common Device Name
FDI, SNARE, FLEXIBLE
Manufacturer (Section D)
COOK ENDOSCOPY
4900 bethania station rd
winston-salem NC 27105
MDR Report Key10985840
Report Number1037905-2020-00545
Device Sequence Number11422098
Product Code FDI
UDI-Device Identifier00827002226470
UDI-Public(01)00827002226470(17)230507(10)W4346126
Combination Product (Y/N)N
Initial Reporter StateCA
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source health professional
Initial Reporter Occupation Nurse
Type of Report Initial,Followup
Report Date (Section B) 01/29/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date05/07/2023
Device Model NumberG22647
Device Catalogue NumberASDB-15-015-S
Device Lot NumberW4346126
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/05/2021
Initial Date Received by Manufacturer 11/18/2020
Supplement Date Received by Manufacturer01/05/2021
Initial Report FDA Received Date12/10/2020
Supplement Report FDA Received Date01/28/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
OLYMPUS PCF-PH190L ENDOSCOPE
Patient Age73 YR
-
-