Model Number PED-500-12
Medical Device Problem Code Activation Failure (3270)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 12/08/2020
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
It was reported that while attempting to open the device, it would not open correctly in the distal section of the pipeline.It was stated it looked like a tulip.More than 50% of the pipeline had been deployed when it failed.It was resheathed less than or equal to 2 times.The pipeline was positioned in a distal part of a bend.No additional steps or other devices were required to open the pipeline.The pipeline was resheathed and removed with the microcatheter from the patient.Angiographic result post procedure was good.The patient was undergoing surgery to treat an unruptured, saccular aneurysm located at the opthalmic artery with a max diameter of 5mm and a neck diameter of 4mm.It was noted the vessel tortuosity was severe.There were no patient symptoms associated with the event.The devices were prepared as indicated in the ifu.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PIPELINE FLEX
Common Device Name
INTRACRANIAL ANEURYSM FLOW DIVERTER
Manufacturer (Section D)
MICRO THERAPEUTICS, INC. DBA EV3
9775 toledo way
irvine CA 92618
MDR Report Key10993291
Report Number2029214-2020-01285
Device Sequence Number3478151
Product Code OUT
UDI-Device Identifier00847536016897
UDI-Public00847536016897
Combination Product (Y/N)N
Initial Reporter StateNY
Initial Reporter CountryUS
PMA/510(K) Number
P100018.S011
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 12/11/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date08/19/2021
Device Model NumberPED-500-12
Device Catalogue NumberPED-500-12
Device Lot NumberA694934
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/08/2020
Initial Report FDA Received Date12/11/2020
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age30 YR
-
-