Model Number MV-F401227
Device Problem Activation Failure (3270)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 11/04/2020
Event Type  Injury  
Manufacturer Narrative
A search for non-conformances associated with the reported part/lot number combination did not reveal any production-related issues relevant to the complaint that occurred during manufacturing of the device.The device was implanted in the patient and not returned to the manufacturer for analysis.Additionally, procedural images were not provided; therefore, the alleged product issue cannot be confirmed.The instructions for use identifies thrombosis as a potential complication associated with use of the device.
 
Event Description
It was reported that after deployment of the fred in the internal carotid artery (ica), the stent did not completely appose to the vessel wall and thrombus developed.Urokinase was administered and the stent was completely expanded with a balloon.There was no reported patient injury or sequela.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FRED 27
Type of Device
FLOW DIVERTER
Manufacturer (Section D)
MICROVENTION, INC.
35 enterprise
aliso viejo CA 92656
Manufacturer Contact
eva manus
35 enterprise drive
aliso viejo, CA 92656
MDR Report Key10998563
MDR Text Key221230006
Report Number2032493-2020-00368
Device Sequence Number1
Product Code OUT
UDI-Device Identifier04987892121845
UDI-Public(01)04987892121845(11)200326(17)230228(10)200326583
Combination Product (y/n)N
Reporter Country CodeJA
PMA/PMN Number
P180027
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Physician
Type of Report Initial
Report Date 12/11/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/13/2020
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date02/28/2023
Device Model NumberMV-F401227
Device Lot Number200326583
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received11/11/2020
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured03/26/2020
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-