B. BRAUN MEDICAL INC. CARESITE; SET, ADMINISTRATION, INTRAVASCULAR Back to Search Results
Model Number 470108
Medical Device Problem Code Fluid/Blood Leak (1250)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
This report has been identified as event 2 of b.Braun medical internal report number (b)(4).The device involved has not been received for evaluation and the investigation is ongoing at this time.A follow up will be submitted when the investigation results become available.
 
Event or Problem Description
Event 2: as reported by the user facility: "when connecting the tubing, there is no tightness.Blood flows at the level of the screw.".
 
Additional Manufacturer Narrative
Event 2: this report has been identified as b.Braun medical internal report number (b)(4).This product was distributed in the eu only and the identified issue had no impact on product available in the u.S.Market.Five used samples were provided for evaluation.Visual examination noted no defects.Leak test was performed and one sample failed.Upon closer examination the sample appears to have been solvent bonded between the spin lock and luer connector which did not allow the connector to seal properly.Signs of solvent were also found on the male luer lock connector.Based on the evaluation of the samples the reported defect is confirmed.Based on the investigation the issue is related to the solvent bonding process during hand assembly.A review of the discrepancy management system (dsms) database was performed for the reported lot number and no abnormalities or non-conformances were noted during the in process or final product inspection.In addition, review of the batch history records was also performed for the reported lot number and no non-conformances or deviations were noted during the manufacturing process or final inspections.We will maintain this report for further references and continue to monitor other reports for similar occurrences.  if any additional pertinent information becomes available, a follow up will be submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CARESITE
Common Device Name
SET, ADMINISTRATION, INTRAVASCULAR
Manufacturer (Section D)
B. BRAUN MEDICAL INC.
901 marcon blvd
allentown 18109
MDR Report Key11020324
Report Number2523676-2020-00354
Device Sequence Number869624
Product Code FPA
UDI-Device Identifier04046964093753
UDI-Public04046964093753
Combination Product (Y/N)N
Initial Reporter CountryFR
PMA/510(K) Number
K942988
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 06/25/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date06/30/2023
Device Model Number470108
Device Catalogue Number470108-01
Device Lot Number0061744004
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/04/2021
Initial Date Received by Manufacturer 12/14/2020
Supplement Date Received by Manufacturer12/14/2020
Initial Report FDA Received Date12/16/2020
Supplement Report FDA Received Date06/25/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-