Model Number MX560
Medical Device Problem Code Break (1069)
Health Effect - Clinical Codes Bradycardia (1751); High Blood Pressure/ Hypertension (1908)
Date of Event 11/25/2020
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Concomitant therapy: ecmo machine.
 
Event or Problem Description
Information was received indicating that a smiths medical tubing pigtail broke off at the crrt access site (pre stopcock) while hoisting the patient up in the bed.There was no noticed stretching of the plastic to make the tubing break.The pigtail was shooting blood out of the ecmo circuit onto the bed and floor.It was clamped off to stop bleeding.A new pigtail and stopcock were primed to resolve the events.Patient was clamped off ecmo for 20 seconds while a new pigtail was placed.Patient became bradycardic into the 30's, and hypertensive.There were no other adverse events reported.
 
Additional Manufacturer Narrative
Other, other text: the device was not returned; however, from the picture provided it appears as though the tubing pulled from the luer connector.The tubing and luer connectors are mated together with the use of solvent to bond them together.Parts are tested by the operators per procedure.Parts are to be tested every hour.Parts are also 100 percent inspected for gaps between the end of the tubing and the end of the luer.This check is in place to identify parts assembled without the proper level of solvent (due to potential air bubbles etc in solvent lines).If parts are found with a gap the lot is written up for an ncmr and sorted.On top of this qc inspectors checked pull tests on the overall lot with a c equals 0 inspection and an aql of 4.00 percent.Without the lot number we are unable to confirm the values of the tested parts during the run of this lot of tubing sets.
 
Event or Problem Description
Additional information was provided detailing that no acls meds were given.The patient's vitals normalized after ecmo flows were restored.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
MEDEX
Common Device Name
SET, ADMINISTRATION, INTRAVASCULAR
Manufacturer (Section D)
SMITHS MEDICAL ASD, INC.
6250 shier rings road
dublin OH 43016
MDR Report Key11052031
Report Number3012307300-2020-12637
Device Sequence Number19552298
Product Code FPA
UDI-Device Identifier10351688506597
UDI-Public10351688506597
Combination Product (Y/N)N
Initial Reporter StateMI
Initial Reporter CountryUS
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source user facility
Initial Reporter Occupation Biomedical Engineer
Type of Report Initial,Followup
Report Date (Section B) 02/09/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberMX560
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Initial Date Received by Manufacturer 11/25/2020
Supplement Date Received by Manufacturer01/12/2021
Initial Report FDA Received Date12/21/2020
Supplement Report FDA Received Date02/09/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other; Required Intervention;
-
-