Model Number 1851-1036S
Medical Device Problem Code Fracture (1260)
Health Effect - Clinical Codes Fall (1848); Failure of Implant (1924); Limb Fracture (4518)
Date of Event 11/01/2020
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Upon completion of investigation, additional information will be provided in a supplemental report.
 
Event or Problem Description
"it was reported via medwatch # (b)(4): "on (b)(6) 2020, patient sustained injury while playing on monkey bars at school.Fell sustaining a per-prosthetic right proximal femur fracture.Fracture was immediately distal to the retained femoral plate.Patient brought to the operating room the next day and underwent removal of blade plate implant and screws, right proximal femur and open reduction of right proximal femur fracture with insertion of intramedullary nail with proximal and distal locking screws.Discharged next day.Patient doing well until one month later.Patient was shooting baskets at school when he felt a pop in his right leg and immediately fell and had significant pain.X-rays showed fractured intramedullary nail through the distal of the 2 proximal locking screw holes.The rod broke in that position, but the bone gave way through the previous area of fracture.After a plan was made to remove the broken femoral nail and then treat the fracture with a standard adult blade plate and appropriate implants and equipment were obtained, patient was brought to the operating room to undergo removal of the broken implant and fixation of his right proximal femur fracture with a fixed angle blade plate.Patient did well and returned to recovery in stable condition.Remains inpatient without incident." additionally reported: "patient does have developmental dysplasia of the hip and type i diabetes, along with charcot-marie-tooth.".
 
Event or Problem Description
"it was reported via medwatch #(b)(4): "on (b)(6) 2020, patient sustained injury while playing on monkey bars at school.Fell sustaining a per-prosthetic right proximal femur fracture.Fracture was immediately distal to the retained femoral plate.Patient brought to the operating room the next day and underwent removal of blade plate implant and screws, right proximal femur and open reduction of right proximal femur fracture with insertion of intramedullary nail with proximal and distal locking screws.Discharged next day.Patient doing well until one month later.Patient was shooting baskets at school when he felt a pop in his right leg and immediately fell and had significant pain.X-rays showed fractured intramedullary nail through the distal of the 2 proximal locking screw holes.The rod broke in that position, but the bone gave way through the previous area of fracture.After a plan was made to remove the broken femoral nail and then treat the fracture with a standard adult blade plate and appropriate implants and equipment were obtained, patient was brought to the operating room to undergo removal of the broken implant and fixation of his right proximal femur fracture with a fixed angle blade plate.Patient did well and returned to recovery in stable condition.Remains inpatient without incident.".Additionally reported: "patient does have developmental dysplasia of the hip and type i diabetes, along with charcot-marie-tooth.".
 
Additional Manufacturer Narrative
The reported event could be confirmed, since physical evaluation revealed a broken nail.The implant was completely broken in the webs of the most distal of the proximal bore ones.A detailed visual inspection of the proximal part revealed a notch at the posterior lateral edge of the proximal bore.The breakage line and residual fracture shows signs of torsional stress and bending load and beyond that the breakage surfaces of both webs presents signs of a fatigue fracture.Although x-ray images and medical reports were requested but without success we received following additional patient details, ¿patient does have developmental dysplasia of the hip and type i diabetes, along with charcot-marie-tooth¿, which were forwarded for a clinical statement by a hcp [excerpts]: ¿¿difficult to assess without an x-ray.Obviously, there had already been an implant failure with a plate.Then the nail was inserted.The boy is 12 has hip dysplasia, diabetes and hereditary neurosensory neuropathy.This results in muscle atrophy and ataxia, which of course can lead to a higher load on the implant.Obviously, full loading was also done.Presumably, all of this with the signs of damage at the implant verified has led to implant failure.This of course remains all conjecture without an x-ray¿¿.What behaviors were advised by the physician for the postoperative period to the patient and whether or not the patient was compliant is unknown.However, according to the reported event, a full load apparently took place again relatively promptly ¿¿patient doing well until one month later.Patient was shooting baskets at school when he felt a pop in his right leg¿¿.Based on details provided it could not be excluded that patient conditions in conjunction with pre-damage of the implant, which is confirmed by signs of damage verified at the most distal of the proximal bore ones, led to the implant failure after an implantation period of approximately one month.Thus, it has to be classified as patient related due to patient conditions and contributed by a pre-damaged implant.A review of the device history for the reported lot did not indicate any abnormalities.No corrective actions are required at this time.A review of the labeling did not indicate any abnormalities.No indications of material, manufacturing or design related problems were found during the investigation.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FEMORAL NAIL, RIGHT T2 GTN 10X360 MM
Common Device Name
ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES
Manufacturer (Section D)
STRYKER TRAUMA KIEL
prof. kuentscher-strasse 1-5
schoenkirchen/kiel D-242 32
GM  D-24232
MDR Report Key11076840
Report Number0009610622-2020-01060
Device Sequence Number3000792
Product Code HSB
UDI-Device Identifier04546540647474
UDI-Public04546540647474
Combination Product (Y/N)N
Initial Reporter StateMO
Initial Reporter CountryUS
PMA/510(K) Number
K101438
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2020
Device Explanted Year2020
Reporter Type Manufacturer
Report Source health professional
Initial Reporter Occupation Risk Manager
Type of Report Initial,Followup
Report Date (Section B) 04/02/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Lay User/Patient
Device Expiration Date06/30/2023
Device Model Number1851-1036S
Device Catalogue Number18511036S
Device Lot NumberK092880
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/01/2021
Initial Date Received by Manufacturer 12/03/2020
Supplement Date Received by Manufacturer03/31/2021
Initial Report FDA Received Date12/28/2020
Supplement Report FDA Received Date04/02/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
Patient Age12 YR
Patient Weight55
-
-