Model Number DR8054
Medical Device Problem Codes Break (1069); Leak/Splash (1354); Material Rupture (1546)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/16/2020
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
As the lot number for the device was provided, a review of the device history record is currently being performed.The device has been returned to the manufacturer for evaluation.The investigation of the reported event is currently underway.(expiry date: 12/2022).
 
Event or Problem Description
It was reported that during an angioplasty procedure of a calcified lesion in the subclavian vein, the pta balloon allegedly ruptured at nominal pressure.The lesion was mildly calcified.There was no reported patient injury.
 
Event or Problem Description
It was reported that during an angioplasty procedure of a calcified lesion in the subclavian vein, the pta balloon allegedly ruptured at nominal pressure.The lesion was mildly calcified.There was no reported patient injury.
 
Additional Manufacturer Narrative
H10: manufacturing review: the device history records have been reviewed and this lot met all release criteria.There was nothing found to indicate there was a manufacturing related cause for this event.Investigation summary: one dorado pta dilatation catheters was returned for evaluation.A visual inspection was performed and device appeared to be bloody.No other anomalies were noted to the device.An in house presto inflation device was used to inflate the device, and a leak was noted to the proximal end of the balloon.A circumferential glue joint break was noted to the proximal end of the balloon under magnification.No other functional test performed, due to condition of the device.Therefore, the investigation is confirmed for the identified glue joint break, as a glue joint break was noted during microscopic evaluation.The investigation is also confirmed for the identified leak issue, as water was noted to be leaking from the proximal balloon joint during functional testing.The investigation is inconclusive for the reported balloon rupture, as functional test could not performed due to condition of the device.The glue joint break noted is the likely cause of the leak.However, the definitive root cause for the reported balloon rupture, identified glue joint break and leak could not be determined based upon available information.Labeling review: the review of the instructions for use, indications, warnings, precautions, cautions, possible complications, and contraindications showed that the product labeling is adequate.H11: section a through f ¿ the information provide by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : see h10.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DORADO PTA DILATATION CATHETER
Common Device Name
PTA BALLOON DILATATION CATHETER
Manufacturer (Section D)
BARD PERIPHERAL VASCULAR, INC.
1625 w 3rd st.
tempe AZ 85281
MDR Report Key11106475
Report Number2020394-2020-21007
Device Sequence Number3922961
Product Code LIT
UDI-Device Identifier00801741058493
UDI-Public(01)00801741058493
Combination Product (Y/N)N
Initial Reporter CountryJA
PMA/510(K) Number
K072283
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 02/22/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberDR8054
Device Catalogue NumberDR8054
Device Lot Number93ZD0127
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer12/03/2020
Initial Date Received by Manufacturer 12/09/2020
Supplement Date Received by Manufacturer03/29/2021
Initial Report FDA Received Date01/04/2021
Supplement Report FDA Received Date04/20/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-