Model Number 04.037.262S
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Arthritis (1723)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Patient identifier: (b)(6).Manufacturing location: (b)(4), manufacturing date: september 20, 2018, expiration date: august 31, 2028, part number: 04.037.262s, 12mm/130 deg ti cann tfna 420mm/right- sterile, lot number: h735696 (sterile), lot quantity: (b)(4).One piece was scrapped in cell at op #30, gundrill, after a tool breakage.Work order traveler met all inspection acceptance criteria apart from the one piece noted.Inspection sheet, in-process / inspect dimensional / final met all inspection acceptance criteria apart from the one piece noted.Inspection sheet, tfna assembly inspection met all inspection acceptance criteria.Packaging label log (pll) lppf , lmd was reviewed and determined to be conforming.Packaging bom was reviewed and determined to be conforming with no deviations to normal packaging identified.Scn 15498 supplied by ethicon (abq) was reviewed and determined to be conforming.This lot met all dimensional, visual, sterility and packaging criteria at the time of release with no issues documented during the manufacture that would contribute to this complaint condition.Component part(s) reviewed: component parts were not reviewed as the reported complaint condition of ¿removal due to terrible arthritis¿ does not indicate breakage of the nail or any of its components.Therefore, review of the raw materials would not be pertinent to the reported complaint condition.This lot met all dimensional, visual, sterility and packaging criteria at the time of release with no issues documented during the manufacture that would contribute to this complaint condition.Product was not returned.Based on the information available, it has been determined that no corrective and preventative action is proposed.This complaint will be accounted for and monitored via post market surveillance activities.If additional information is made available, the investigation will be updated as applicable.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
It was reported that on (b)(6) 2020, the patient underwent a hardware removal of nail, helical blade, and locking screws followed by a total hip replacement surgery due to terrible arthritis.Initially, the patient was implanted with a trochanteric femoral nail advanced (tfna) on an unknown date.The hardware removal and total hip replacement surgery was successfully completed.There was no patient consequence.Concomitant devices reported: tfna fenestrated helical blade 100mm (part number 04.038.400, lot h556431, quantity 1); 5.0mm ti locking screw w/t25 stardrive 48mm for im nails (part number 04.005.538, lot unknown, quantity 1); 5.0mm ti locking screw w/t25 stardrive 48mm for im nails (part number 04.005.538, lot unknown, quantity 1).This report involves one (1) 12mm/130 deg ti cann tfna 420mm/right-sterile.This is report 1 of 4 for (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
12MM/130 DEG TI CANN TFNA 420MM/RIGHT-STERILE
Common Device Name
ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES
Manufacturer (Section D)
WRIGHTS LANE SYNTHES USA PRODUCTS LLC
1302 wrights lane east
west chester PA 19380
MDR Report Key11139918
Report Number2939274-2021-00124
Device Sequence Number17043039
Product Code HSB
UDI-Device Identifier10886982097422
UDI-Public(01)10886982097422
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
K160167
Number of Events Summarized1
Summary Report (Y/N)N
Device Explanted Year2020
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 12/14/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model Number04.037.262S
Device Catalogue Number04.037.262S
Device Lot NumberH735696
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 12/14/2020
Initial Report FDA Received Date01/08/2021
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
5.0MM TI LOCKING SCREW; 5.0MM TI LOCKING SCREW; TFNA FENESTRATED HELICAL BLADE
Outcome Attributed to Adverse Event Required Intervention;
Patient Age68 YR
-
-