Model Number 408310
Device Problems Material Separation (1562); Obstruction of Flow (2423)
Patient Problems No Consequences Or Impact To Patient (2199); No Clinical Signs, Symptoms or Conditions (4582)
Event Date 10/12/2020
Event Type  malfunction  
Manufacturer Narrative
The results/method and conclusion codes along with investigation results will be provided in the final report.
 
Event Description
During device preparation, the sheath was opened and placed on the sterile equipment table.When saline was flushed through the sheath, the liquid would not flush through the sheath.Then a new flush syringe was used to attempt to flush the sheath, but the issue persisted.The sheath was removed from the table and set aside while a replacement was opened and used instead.The sideport was also noted to have been detached outside of the patient.There was no patient consequences.
 
Manufacturer Narrative
One 8.5f agilis steerable introducer sheath was returned for evaluation.The sideport tubing was no longer attached to the hemostasis body confirming the field reported event of the sideport detaching.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AGILIS¿ NXT STEERABLE INTRODUCER DUAL-REACH¿ 71 CM SHEATH, MEDIUM CURL, 8.5 F
Type of Device
INTRODUCER, CATHETER
Manufacturer (Section D)
ST. JUDE MEDICAL
parque industrial, zona franca coyol s.a.
edificio #44b, calle 0, avenida 2, coyol
alajuela, costa rica 1897- 4050
CS  1897-4050
Manufacturer (Section G)
ST. JUDE MEDICAL
parque industrial, zona franca coyol s.a.
edificio #44b, calle 0, avenida 2, coyol
alajuela, costa rica 1897- 4050
CS   1897-4050
Manufacturer Contact
stephanie o' sullivan
5050 nathan lane north
plymouth, MN 55442
6517565400
MDR Report Key11142139
MDR Text Key226060183
Report Number3008452825-2020-00706
Device Sequence Number1
Product Code DYB
UDI-Device Identifier05414734206105
UDI-Public05414734206105
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K061363
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Health Professional,Company Representative
Reporter Occupation Physician
Type of Report Initial,Followup,Followup
Report Date 07/20/2023
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date04/30/2023
Device Model Number408310
Device Catalogue Number408310
Device Lot Number7508166
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/27/2020
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 12/11/2020
Initial Date FDA Received01/08/2021
Supplement Dates Manufacturer Received02/16/2021
02/16/2021
Supplement Dates FDA Received02/16/2021
07/20/2023
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured05/08/2020
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-