Model Number DL900F
Device Problems Detachment of Device or Device Component (2907); Patient Device Interaction Problem (4001)
Patient Problems Chest Pain (1776); Device Embedded In Tissue or Plaque (3165)
Event Date 05/18/2017
Event Type  Injury  
Manufacturer Narrative
Manufacturing review: a lot history review was performed.This is the only complaint to date for this lot number.Therefore, a device history record review is not required.Investigation summary: the device was not returned for evaluation.Medical records were provided and reviewed.Approximately one year and three months later, the patient presented for filter removal, the right internal jugular vein was percutaneously cannulated followed by guidewire insertion into the central venous system.The removal sheet was then inserted and placed above the filter.A diagnostic inferior venacavogram was performed to exclude the presence of any neighboring thrombus and there was none.The cone filter removal system was then inserted through the sheath and placed over the filter which was easily engaged.The coaxial sheath was then slid down over the cone and the filter was dislodged and easily removed.After one year and one month, stable linear radiodensity in the left perihilar region, corresponding to a radiopaque density in a left lower lobe pulmonary artery on chest computed tomography, which may represent an embolized leg from an old filter which was removed 1-2 years ago.The patient experienced chest pain.After two weeks, chest x-ray 2 views revealed possible retained limp of the filter in left segmental superior pulmonary artery of lower lobe.Therefore, the investigation is confirmed for alleged filter limb detachment.However, the investigation is inconclusive for alleged perforation of the inferior vena cava.Based upon the available information, the definitive root cause is unknown.Labeling review: a review of product labeling documents (e.G.Procedural instructions, indications, warnings, precautions, cautions, possible complications, contraindications, and unit label) showed that the product labeling is adequate.(expiry date: 08/2017).
 
Event Description
It was reported through the litigation process that a vena cava filter was placed in a patient after being diagnosed with deep vein thrombosis/pulmonary embolism.At some time post filter deployment, it was alleged that the filter detached and struts perforated into organs.The device was removed percutaneously.It was further reported that the detached strut remained in left segmental superior pulmonary artery of lower lobe; however, the current status of the patient is unknown.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DENALI FEMORAL SYSTEM
Type of Device
VENA CAVA FILTER
Manufacturer (Section D)
BARD PERIPHERAL VASCULAR, INC.
1625 w 3rd st.
tempe AZ 85281
Manufacturer (Section G)
C.R. BARD, INC. (GFO)
289 bay road
queensbury NY 12804
Manufacturer Contact
judith ludwig
1415 w. 3rd street
tempe, AZ 85281
4803032689
MDR Report Key11162847
MDR Text Key226549265
Report Number2020394-2020-06546
Device Sequence Number1
Product Code DTK
UDI-Device Identifier00801741040801
UDI-Public(01)00801741040801
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K130366
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer,health professional
Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date 01/13/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/13/2021
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberDL900F
Device Catalogue NumberDL900F
Device Lot NumberGFYG3610
Was Device Available for Evaluation? No
Date Manufacturer Received12/21/2020
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
Patient Age51 YR
-
-