Model Number 213041-LVIS-D-PMA
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 12/17/2020
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
A search for non-conformance associated with this part/lot number combination did not reveal any production-related issues relevant to the complaint that occurred during manufacturing of the device.The device was implanted in the patient and the delivery system was not returned to the manufacturer for analysis.Intraprocedural or post-procedural images were not provided for review; therefore, the alleged product issue cannot be confirmed.
 
Event or Problem Description
It was reported that after deployment of an lvis in the internal carotid artery (ica) to treat a ruptured aneurysm, the proximal markers of the stent did not open.The markers could not be opened with the catheters.No additional intervention was performed.Final angiography demonstrated a mostly patent ica and the aneurysm was successfully coiled.There was no reported patient injury or sequela.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LVIS D
Common Device Name
INTRALUMINAL SUPPORT DEVICE
Manufacturer (Section D)
MICROVENTION, INC.
35 enterprise
aliso viejo CA 92656
MDR Report Key11182426
Report Number2032493-2021-00017
Device Sequence Number16861553
Product Code QCA
UDI-Device Identifier00842429100967
UDI-Public(01)00842429100967(11)180619(17)210531(10)18061953B
Combination Product (Y/N)N
Initial Reporter StateSC
Initial Reporter CountryUS
PMA/510(K) Number
P170013
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2020
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 11/15/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Other
Device Expiration Date05/31/2021
Device Model Number213041-LVIS-D-PMA
Device Catalogue Number213041-LVIS
Device Lot Number18061953B
Was Device Available for Evaluation? No
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 12/17/2020
Initial Report FDA Received Date01/15/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No