SMITH & NEPHEW ORTHOPAEDICS AG SL-PLUS/SBG/IPA MIA OFFSET ADAPTER 40MM; PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, CEMENTED Back to Search Results
Model Number 75007308
Medical Device Problem Code Fracture (1260)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 12/28/2020
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Complaint reference: case-(b)(4).
 
Event or Problem Description
It was reported that an attachment of the plus sl-plus mia dbl offset adapt.Has broken off in large knock plate while broach was impacted into patient.Procedure was completed using a s+n backup device.No surgical delay or injury to the patient was reported.
 
Additional Manufacturer Narrative
Investigation results:it was reported that the attachment of the plus sl-plus mia double offset adapter has broken off in the large knock plate while the broach was impacted into the patient.The procedure was completed using a smith and nephew backup device.No surgical delay or injury to the patient was reported.The device, used in treatment, was returned for investigation.Upon visual inspection, the fracture at the connection between the contact pin and the body of the adapter could be confirmed.Apart from that, the device shows normal signs of usage such as small dents and scratches.According to document "processing (cleaning, disinfection and sterilization) of instruments from smith & nephew orthopaedics ag" (lit.N°03389-en 1363 v3 11/19), all instruments must be inspected and controlled for proper functioning after cleaning/disinfection.Instruments should only be used in their original condition (lit.No.12.23 ed.05/16).Furthermore, the failure mode and the severity are covered through our risk management.Review of the production documentation did not detect any deviation that could have contributed to the reported failure mode.Possible material certificates of the batch in question were additionally reviewed, but no deviation was detected as well.No additional complaint was detected for the batch in question (h58205).A medical investigation could not be performed as relevant clinical information has not been provided.This instrument is designed to hold and guide the detachable rasps for broaching.It is therefore subjected to repeated impact forces via the modular knock plate or the pneumatic woodpecker.Previous investigations demonstrated, that under specific circumstances, this device may fracture during impaction.An optimized design of the device has been released in order to reduce the occurrence of this issue.This version of the device will be monitored for similar issues.The returned device will be discarded.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SL-PLUS/SBG/IPA MIA OFFSET ADAPTER 40MM
Common Device Name
PROSTHESIS, HIP, SEMI-CONSTRAINED, METAL/POLYMER, CEMENTED
Manufacturer (Section D)
SMITH & NEPHEW ORTHOPAEDICS AG
schachenallee 29
aarau CH-50 00
SZ  CH-5000
MDR Report Key11183308
Report Number9613369-2021-00036
Device Sequence Number11562762
Product Code JDI
UDI-Device Identifier07611996074895
UDI-Public07611996074895
Combination Product (Y/N)N
Initial Reporter StateMI
Initial Reporter CountryUS
PMA/510(K) Number
K123598
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative,user f
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 03/23/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number75007308
Device Catalogue Number75007308
Device Lot NumberH58205
Was Device Available for Evaluation? Yes
Initial Date Received by Manufacturer 12/28/2020
Supplement Date Received by Manufacturer03/19/2021
Initial Report FDA Received Date01/17/2021
Supplement Report FDA Received Date03/23/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
-
-