WARSAW ORTHOPEDICS PYRAMESH C TITANIUM MESH; MESH, SURGICAL, METAL Back to Search Results
Model Number 905-137
Medical Device Problem Code Fracture (1260)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 11/17/2020
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
Information was received from healthcare provider via manufacturing representative via manufacturing representative regarding patient with spinal degeneration suggested for spinal therapy.Event occurred intra-op.It was reported that when the titanium mesh was cut in vitro, the titanium mesh fractured.No patient symptoms or further complications were reported.Device is being returned.
 
Additional Manufacturer Narrative
Product analysis of product # 905-137 ; lot # 0757114w analysis summary: visual and optical inspection confirmed the mesh has been cut/broken in 4 pieces.Optical inspection did not reveal any damage that would contribute to the implant breaking unintentionally.Unable to determine root cause of broken implant.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PYRAMESH C TITANIUM MESH
Common Device Name
MESH, SURGICAL, METAL
Manufacturer (Section D)
WARSAW ORTHOPEDICS
2500 silveus crossing
warsaw IN 46582
MDR Report Key11206612
Report Number1030489-2021-00092
Device Sequence Number4532636
Product Code EZX
UDI-Device Identifier00673978080659
UDI-Public00673978080659
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K011406
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 06/14/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number905-137
Device Catalogue Number905-137
Device Lot Number0757114W
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/22/2021
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 01/04/2021
Supplement Date Received by Manufacturer05/25/2021
Initial Report FDA Received Date01/21/2021
Supplement Report FDA Received Date06/14/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age44 YR
-
-