| Model Number |
VENUM14140 |
| Medical Device Problem Codes |
Difficult to Remove (1528); Activation Failure (3270)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
10/23/2020
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
As the lot number for the device was provided, a review of the device history record is currently being performed.The device has not been returned to the manufacturer for evaluation.However, images were provided for review.The investigation of the reported event is currently underway.(expiry date: 08/2022).The information provide by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
|
| |
|
Event or Problem Description
|
|
It was reported that during a treatment in the internal jugular, the device allegedly difficult to remove.It was further reported that, the stent was removed.There was no reported patient injury.
|
| |
|
Additional Manufacturer Narrative
|
|
H10: manufacturing review: the lot history record of this lot was reviewed with special attention to the manufacturing and inspection of this product, and the product was found to have met the specification prior to shipment.Investigation summary: the physical sample was not available.One image was provided demonstrating bilaterally placed stents inside the iliac veins with bilaterally lying guidewires.The stent was visibly constricted in the area of the silicone stent brake.Distal and proximal of that section the stent was regularly expanded so that it appeared like an hour-glass with the guidewire visible very close to the stent wall which indicated that the deployment sheath was retracted and that the stent adhered to the silicone brake, which leads to a confirmed result for expansion issue.Based on the information available the investigation is closed with confirmed result.A definite root cause for the reported event could not be determined.Labeling review: a review of the relevant instructions for use for this product was conducted.The instructions for use was found to address potential complications and adverse events such as incorrect positioning of the stent requiring further stenting or surgery, intimal injury, and malposition.H10: d4 (expiry date: 08/2022).H11: h6(method, result).H11: section a through f: the information provide by bd represents all the known information at this time.Despite good faith efforts to obtain additional information, the complainant/reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.H3 other text : device not returned.
|
| |
|
Event or Problem Description
|
|
It was reported that during a treatment in the internal jugular, the device allegedly difficult to remove.It was further reported that, the stent was removed.There was no reported patient injury.
|
| |
|