Model Number 1867
Medical Device Problem Code Detachment of Device or Device Component (2907)
Health Effect - Clinical Codes No Consequences Or Impact To Patient (2199); No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/06/2021
Type of Reportable Event Malfunction
Event or Problem Description
It was reported that the collar was fractured.The 90% stenosed target lesion was located in the mildly tortuous and mildly calcified right coronary artery.A guidezilla guide extension catheter was selected for use.During procedure, it was noted that the collar was fractured.The device was simply pulled out completely from the patient's body.The procedure was completed with another of the same device.No complications reported and patient was stable.
 
Additional Manufacturer Narrative
Device evaluated by manufacturer: the device was returned for analysis.Analysis of the tip, distal shaft, collar and hypotube included microscopic and visual inspection.Inspection revealed a partial separation at the shaft/collar area, and the collar was damaged (edge lifted away from collar).Inspection of the rest of the device found no other damage or defect.
 
Event or Problem Description
It was reported that the collar was fractured.The 90% stenosed target lesion was located in the mildly tortuous and mildly calcified right coronary artery.A guidezilla guide extension catheter was selected for use.During procedure, it was noted that the collar was fractured.The device was simply pulled out completely from the patient's body.The procedure was completed with another of the same device.No complications reported and patient was stable.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
GUIDEZILLA
Common Device Name
CATHETER, PERCUTANEOUS
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
MDR Report Key11223268
Report Number2134265-2021-00636
Device Sequence Number14387654
Product Code DQY
UDI-Device Identifier08714729839859
UDI-Public08714729839859
Combination Product (Y/N)N
Initial Reporter CountryCH
PMA/510(K) Number
K123765
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source company representative,distri
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 03/17/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date07/23/2022
Device Model Number1867
Device Catalogue Number1867
Device Lot Number0025758717
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/28/2021
Initial Date Received by Manufacturer 01/12/2021
Supplement Date Received by Manufacturer02/26/2021
Initial Report FDA Received Date01/25/2021
Supplement Report FDA Received Date03/17/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age58 YR
Patient Weight62
-
-