OLYMPUS MEDICAL SYSTEMS CORP. SINGLE USE ASPIRATION NEEDLE NA-U401SX Back to Search Results
Model Number NA-U401SX-4022
Medical Device Problem Code Mechanical Problem (1384)
Health Effect - Clinical Code No Consequences Or Impact To Patient (2199)
Date of Event 12/23/2020
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
The device referenced in this report has not been returned to olympus for evaluation.The investigation is ongoing.The definitive cause of the customer's experience cannot be determined at this time.This report will be updated upon completion of the investigation or upon receipt of additional relevant information.
 
Event or Problem Description
It is reported a single use aspiration needle would not lock.The sheath would not stay locked and the needle came out puncturing the insertion tube of the scope.There was no patient impact related to this occurrence.
 
Additional Manufacturer Narrative
This report is being supplemented to provide additional information based on the legal manufacturer's investigation.A review of the device history record found no deviations that could have caused or contributed to the reported issue.The device was returned and evaluated, however the reported issue was not confirmed.Based on the results of the legal manufacturer's investigation, from the results of past investigations, it is likely that the reason why the needle could not be fixed is due to the needle adjuster being in a convex position.A review of the instruction manual confirms the following verbiage: "before pushing in the needle slider, make sure that the needle adjuster is firmly fixed.If the needle adjuster is not firmly fixed, the needle may pop out from the tip of the sheath beyond the intended length, leading to perforation, major bleeding, and mucosal damage"."when fixing the needle adjuster lever, if there is resistance during the operation of fixing the needle adjuster lever, release the needle adjuster lever once and fix it again.Forcibly fixing the needle while there is resistance may damage the needle adjuster lever, prevent the needle adjuster from being fixed, and cause the needle to protrude beyond the intended length, leading to perforation, major bleeding, and/or mucosal damage".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SINGLE USE ASPIRATION NEEDLE NA-U401SX
Common Device Name
SINGLE USE ASPIRATION NEEDLE
Manufacturer (Section D)
OLYMPUS MEDICAL SYSTEMS CORP.
2951 ishikawa-cho
hachioji-shi, tokyo-to 192-8 507
JA  192-8507
MDR Report Key11237410
Report Number8010047-2021-01928
Device Sequence Number3721104
Product Code FCG
UDI-Device Identifier04953170388286
UDI-Public04953170388286
Combination Product (Y/N)N
Initial Reporter StateIN
Initial Reporter CountryUS
PMA/510(K) Number
K160098
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source user facility
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 03/16/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model NumberNA-U401SX-4022
Device Lot NumberKR108363
Was Device Available for Evaluation? Yes
Was the Report Sent to FDA? No
Initial Date Received by Manufacturer 01/04/2021
Supplement Date Received by Manufacturer03/01/2021
Initial Report FDA Received Date01/27/2021
Supplement Report FDA Received Date03/16/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-