• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: WRIGHTS LANE SYNTHES USA PRODUCTS LLC 3.5MM VARIABLE ANGLE LOCKING SCREW/SLF-TPNG/STRDRV/75MM; SCREW,FIXATION,BONE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

WRIGHTS LANE SYNTHES USA PRODUCTS LLC 3.5MM VARIABLE ANGLE LOCKING SCREW/SLF-TPNG/STRDRV/75MM; SCREW,FIXATION,BONE Back to Search Results
Model Number 02.127.175
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Additional product code hrs complainant part is not expected to be returned for manufacturer review/investigation.Without a lot number, the device history records review could not be completed as no product was received.The investigation could not be completed, no product was received; no conclusion could be drawn at the time of filing this report.Device was used for treatment, not diagnosis.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
It was reported that on (b)(6) 2021 the surgeon was removing a plate and 9 screws from this patient.During the removal 3 of the 3.5mm screw heads broke off into the patient.These 3 screws remained in the patient.He also removed a plate and 6 screws all of which were removed successfully.Procedure was completed successfully.It is unknown if there were fragments generated.It is unknown if there were surgical delay and patient consequence.This complaint involves ten (10) devices.This report is for (1) 3.5mm variable angle locking screw/slf-tpng/strdrv/75mm.This is report 9 of 10 (b)(4).Related product complaint: (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
3.5MM VARIABLE ANGLE LOCKING SCREW/SLF-TPNG/STRDRV/75MM
Common Device Name
SCREW,FIXATION,BONE
Manufacturer (Section D)
WRIGHTS LANE SYNTHES USA PRODUCTS LLC
1302 wrights lane east
west chester PA 19380
MDR Report Key11274512
Report Number2939274-2021-00659
Device Sequence Number14364728
Product Code HWC
UDI-Device Identifier10886982043375
UDI-Public(01)10886982043375
Combination Product (Y/N)N
Initial Reporter StateFL
Initial Reporter CountryUS
PMA/510(K) Number
K121601
Number of Events Summarized1
Summary Report (Y/N)N
Device Explanted Year2021
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source company representative,health
Initial Reporter Occupation Physician
Type of Report Initial
Report Date (Section B) 01/14/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device Health Professional
Device Model Number02.127.175
Device Catalogue Number02.127.175
Was Device Available for Evaluation? No
Type of Report(Section G)Initial
Initial Date Received by Manufacturer 01/14/2021
Initial Report FDA Received Date02/03/2021
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
2.4MM CRTX SCRW 3.5MM HEAD/SLF-TPNG 40MM; 3.5MM CORTEX SCREW SELF-TAPPING 40MM; 3.5MM CORTEX SCREW SELF-TAPPING 80MM; 3.5MM TI CORTEX SCREW SELF-TAPPING/80MM; 3.5MM VA-LCP PRX TBIA PLT SM BND/6H/117MM/LFT; 3.5MM VBLE ANG LKNG SRW/SLF-TPN/STDRV/75MM; 3.5MM VBLE ANG LKNG SRW/SLF-TPN/STDRV/75MM; 3.5MM VBLE ANG LKNG SRW/SLF-TPN/STDRV/75MM; 3.5MM VBLE ANG LKNG SRW/SLF-TPN/STDRV/75MM
Outcome Attributed to Adverse Event Required Intervention;
Patient Age32 YR
-
-