Model Number SL-611
Medical Device Problem Code Unraveled Material (1664)
Health Effect - Clinical Codes Wound Dehiscence (1154); Swelling/ Edema (4577); No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 01/10/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event or Problem Description
According to the reporter, two days post-operatively, a sterilization procedure of the dog, it was noticed that the wound was swollen.On another appointment about four days post-operatively, it was noted that there was a dehiscence of the linea alba sutures.The middle continuous layer of the suture had completely pulled apart, both knots were still firmly in place but the suture material had broken off just caudal to cranial knot.A repair surgery was done and all organs were checked and the anastomosis was re-sutured using a different suture.There was no patient injury.
 
Additional Manufacturer Narrative
Evaluation summary: medtronic conducted an investigation based upon all information received.Twenty one representative samples sealed with the appropriate packaging were received for evaluation.The evaluation found no potentially contributing factors.It was reported that the suture line did not hold after application.The reported issue could not be confirmed.The most likely cause could not be identified because no related problem was detected with the device.The manufacturing records for each device are thoroughly reviewed prior to release to ensure that it meets all medtronic quality specifications.Medtronic is submitting this report to comply with fda reporting regulations under 21 cfr parts 4 and 803.This report is based upon information obtained by medtronic, which the company may not have been able to fully investigate or verify prior to the date the report was required by the fda.Medtronic has made reasonable efforts to obtain more complete information and has provided as much relevant information as is available to the company as of the submission date of this report.This report does not constitute an admission or a conclusion by fda, medtronic, or its employees that the device, medtronic, or its employee caused or contributed to the event described in the report.In particular, this report does not constitute an admission by anyone that the product described in this report has any ¿defects¿ or has ¿malfunctioned¿.These words are included in the fda 3500a form and are fixed items for selection created by the fda to categorize the type of event solely for the purpose of regulatory reporting.Medtronic objects to the use of these words and others like them because of the lack of definition and the connotations implied by these terms.This statement should be included with any information or report disclosed to the public under the freedom of information act.Any required fields that are unpopulated are blank because the information is currently unknown or unavailable.A good faith effort will be made to obtain the applicable information relevant to the report.If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
POLYSORB
Common Device Name
SUTURE, ABSORBABLE, SYNTHETIC, POLYGLYCOLIC AC
Manufacturer (Section D)
DAVIS & GECK CARIBE LTD
zona franca de san isidro
santo domingo 0101
DR  0101
MDR Report Key11303020
Report Number9612501-2021-00231
Device Sequence Number14294882
Product Code GAM
UDI-Device Identifier10884521048898
UDI-Public10884521048898
Combination Product (Y/N)N
Initial Reporter CountryUK
PMA/510(K) Number
K963253
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 06/03/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date06/30/2025
Device Model NumberSL-611
Device Catalogue NumberSL-611
Device Lot NumberD0G1857FY
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/12/2021
Initial Date Received by Manufacturer 01/15/2021
Supplement Date Received by Manufacturer05/19/2021
Initial Report FDA Received Date02/09/2021
Supplement Report FDA Received Date06/03/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Patient Age1 YR
-
-