Model Number 88-9199
Health Effect - Clinical Codes No Consequences Or Impact To Patient (2199); No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/02/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Pr # (b)(4) - 04feb2021 writer sent the customer an email acknowledging receipt of the complaint, providing the complaint tracking number and requested follow up information including as to if there was any patient impact related to this event.Writer provided contact information.Device not yet evaluated, if the device is evaluated a follow up will be sent.
 
Event or Problem Description
Hold for marlo 2.17 per email: event description per attached email states: i received a call from a customer who stated the cord burned completely through at the blue end that connects to instrument during surgery.Doctor is concerned this could be a bad lot.Material no.: 88-9199; lot no.: 110882.Doe: (b)(6) 2021.No injuries.15feb2021 additional information: cut/coag was set at 30/30.Surgeon was using cord and disposable laparoscopic hook auto suture scissors laparoscopic cholecystectomy.No further information available.
 
Event or Problem Description
Event description per attached email states: i received a call from a customer who stated the cord burned completely through at the blue end that connects to instrument during surgery.Doctor is concerned this could be a bad lot.Material no.: 88-9199; lot no.: 110882.Doe: (b)(6) 2021.No injuries.15feb2021 additional information: cut/coag was set at 30/30.Surgeon was using cord and disposable laparoscopic hook auto suture scissors laparoscopic cholecystectomy.No further information available.
 
Additional Manufacturer Narrative
Follow up (b)(4).The complaint product was returned, and an evaluation was performed.The product at the time of manufacturing would have conformed to all specifications for the production.The root cause for the reported issue is most likely due to wear during maintenance/processing, excessive use, and sterilization, and appears to have reached end of life.The product was returned for evaluation.We were able to confirm that the lot number on the device was 110882.This lot number was sold to carefusion in (b)(6) 2018.Based on this information, the product has been in use for approximately two years and two months.Upon our evaluation of the product, it was noted the device showed significant signs of wear and tear.This wear and tear occurred over the two year and two-month time period it was in use.This product has a recommendation of twenty uses.Extensive bending at the instrument end will cause the wires to wear over time and short out internally.The probable root cause has been determined to be extensive use over two years and two months that caused wear and tear to the internal wiring.There have been no issues identified with the material or manufacturing process.A review of the device history records (dhr) did not identify and issues that would have contributed to the reported issue.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNIPOLAR BOVIE CORD W/UNIVERSAL PLUG
Common Device Name
ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES
Manufacturer (Section D)
CAREFUSION, INC
75 north fairway drive
vernon hills IL 60061
MDR Report Key11338144
Report Number1423507-2021-00005
Device Sequence Number3483690
Product Code GEI
UDI-Device Identifier10885403154805
UDI-Public(01)10885403154805
Combination Product (Y/N)N
Initial Reporter StateIL
Initial Reporter CountryUS
PMA/510(K) Number
K971540
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source other,user facility
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date (Section B) 03/15/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number88-9199
Device Catalogue Number88-9199
Device Lot Number110882
Initial Date Received by Manufacturer 02/02/2021
Supplement Date Received by Manufacturer02/02/2021
Initial Report FDA Received Date02/17/2021
Supplement Report FDA Received Date03/15/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-