| Model Number |
656316 |
| Medical Device Problem Code |
Positioning Failure (1158)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
01/27/2021
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Upon completion of investigation, additional information will be provided in a supplemental report.
|
| |
|
Event or Problem Description
|
|
"it was reported that during a right distal radius plate implantation, screws would not lock into several of the distal locking holes of the plate.Overall, 14 screws were wasted.Plate was successfully implanted with a surgical delay of approximately 1 hour.".
|
| |
|
Additional Manufacturer Narrative
|
|
Correction: refer to d9/h3 device availability.The reported event could not be confirmed, since the device was not returned for evaluation and no other evidences were provided.More detailed information about the complaint event as well as the affected device must be available in order to determine the root cause of the complaint event.However, a potential non-conformity report was initiated to address a similar event.The comprehensive root cause analysis of the potential ncr included a surface and microstructure analysis as well as nano-indent hardness measurement of variax1 and variax2 screw samples by the fraunhofer institute on behalf of stryker.Further internal investigation efforts were focusing on the anodization color difference between variax1 and variax2 screws.Significant differences between the screws which could result in the reported complaints have not been revealed in either fraunhofer or stryker investigations.Excessive in-house handling and bench testing with variax2 screws from various manufacturing batches showed that locking is achieved as intended.The desired increase in torque indicating to the customer that the screw is locking in the plate, can be confirmed.A review of the device history was not possible because the lot number was not communicated.No corrective actions are required at this time.A review of the labeling did not indicate any abnormalities.No indications of material, manufacturing or design related problems were found during the investigation.If the device is returned or if any additional information is provided, the investigation will be reassessed.H3 other text : device disposition is unknown.
|
| |
|
Event or Problem Description
|
|
"it was reported that during a right distal radius plate implantation, screws would not lock into several of the distal locking holes of the plate.Overall, 14 screws were wasted.Plate was successfully implanted with a surgical delay of approximately 1 hour".
|
| |
|
Search Alerts/Recalls
|