Model Number 460
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/02/2021
Type of Reportable Event Malfunction
Additional Manufacturer Narrative
Investigation: the run data file (rdf) was analyzed for this event.The analysis of the run data file did not find a conclusive cause for the higher-than-expected wbc content in the platelet product reported for this collection.No unusual process variable was identified and the signals in the run data file indicate that the trima accel system operated as intended.Based on the available information, it cannot be ruled out that the higher-than-expected wbc content in the platelet product could be donor-related.Investigation is in process.A follow-up report will be provided.
 
Event or Problem Description
The customer would like the run data file investigated to determine a possible cause for the elevated white blood cell (wbc) content in the platelet product.There was not a transfusion recipient or patient involved at the time of the residual white blood cell (rwbc) testing, therefore no patient information is reasonably known at the time of the event.Donor unit #: (b)(6).The platelet collection set is not available for return because it was discarded by the customer.
 
Additional Manufacturer Narrative
This report is being filed to provide additional information in h.6 and h.10.Investigation: the device history records (dhr) were reviewed for this lot.There were no events noted in the dhr that would have contributed to the elevated wbc count experienced by the customer.Investigation is in process.A follow-up report will be provided.
 
Additional Manufacturer Narrative
This report is being filed to provide root cause: the analysis of the run data file did not find a conclusive cause for the higher-than- expected wbc content in the platelet product reported for this collection.No unusual process variable was identified and the signals in the run data file indicate that the trima accel system operated as intended.Based on the available information, it cannot be ruled out that the higher- than-expected wbc content in the platelet product could be donor-related.Regarding the high yield of the platelet product, a definitive root cause could not be determined.Possible causes include but are not limited to: ¿ entry of incorrect donor characteristics including pre platelet count, hematocrit, height and weight.Incorrectly configured machine variables (i.E.Target yield not accurate, inaccurate yield scaling factor).Sampling aliquot contains platelet aggregates which could lead to a higher platelet count once the aggregates are dispersed.¿ improper resting and mixing of platelet product prior to sampling.Improper sampling technique and dilution.Inaccurate yield scaling factor.Use of a scale or cell counter that is not calibrated.Use of improper tare weight and/or specific gravity to calculate product volume.Variability of supplied parts or misassembly in the set.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
TRIMA ACCEL
Common Device Name
TRIMA ACCEL PLATELET + SAMPLER AUTO PAS, MULTIPLASMA
Manufacturer (Section D)
TERUMO BCT
lakewood CO 80215
MDR Report Key11405443
Report Number1722028-2021-00089
Device Sequence Number19984086
Product Code GKT
UDI-Device Identifier20613031824602
UDI-Public20613031824602
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
PMA/510(K) Number
BK190332
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source health professional
Initial Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup,Followup
Report Date (Section B) 03/03/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Expiration Date10/01/2022
Device Model Number460
Device Catalogue Number82460
Device Lot Number2010161130
Was Device Available for Evaluation? No
Was the Report Sent to FDA? Yes
Type of Report(Section G)Thirty-Day
Initial Date Received by Manufacturer 02/10/2021
Supplement Date Received by Manufacturer06/04/2021
08/06/2021
Initial Report FDA Received Date03/03/2021
Supplement Report FDA Received Date06/23/2021
08/26/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Other;
-
-