|
ETHICON INC. PROLENE SUT 30IN(75CM) 0 BLU; SUTURE, NONABSORBABLE, SYNTHETIC, POLYPROPYLENE
|
Back to Search Results |
|
| Model Number |
8424H |
| Medical Device Problem Code |
Material Separation (1562)
|
| Health Effect - Clinical Code |
No Clinical Signs, Symptoms or Conditions (4582)
|
| Date of Event |
01/01/2021
|
|
Type of Reportable Event
|
Malfunction
|
|
Additional Manufacturer Narrative
|
|
Product complaint # (b)(4).Note: events reported in 2210968-2021-01963, 2210968-2021-01959, and 2210968-2021-01960.To date, the device has not been returned.If the device or further details are received, a supplemental medwatch will be received.Attempts are being made to obtain the following information.To date, no response has been provided.If further details are received at a later date, a supplemental med watch will be sent.Could you please confirm how many devices presented suture pull off from needle during this single procedure? please specify if more than one procedure was affected.What was being done when the sutures pulled off (e.G.Removal from package, during passage through tissue, during tying, post-op, etc.)? what tissue was being approximated or sutured when the pull off occurred? were there any patient consequences? could you please provide event date? procedure name and date? device return status/follow up.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
|
| |
|
Event or Problem Description
|
|
It was reported that a patient underwent an unknown procedure on an unknown date and suture was used.During the procedure, the suture broke off from the needle.There were no adverse patient consequences reported.Additional information was requested.
|
| |
|
Additional Manufacturer Narrative
|
|
(b)(4), date sent to the fda: 4/7/2021.This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by ethicon inc, or its employees that the report constitutes an admission that the product, ethicon inc or its employees caused or contributed to the potential event described in this report.If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.Additional information: d9, h6.A manufacturing record evaluation was performed for the finished device batch pch857 and no non-conformances were identified.Additional h3 investigation summary: the product was returned for evaluation visual inspection and functional testing were conducted on the returned devices.Visual analysis of the returned sample determined that an empty opened box and twenty-three unopened samples of product code 8424h were received for evaluation.Visual inspection of thirteen unopened samples and no defects were found on the package.The samples were opened, and the swage and attachment area was noted to be as expected.The sutures were dispensed without problems and examined along the strand and no defects or damage were observed.A functional test was performed and the pull force and the samples meet the minimum ltl however the average did not meet requirement.Due to the average did to meet with the requirements the rest of the samples were test by needle pull.According to functional test by needle pull, the reported complaint is confirmed, since the results did not meet with the finished goods requirements by average.(b)(4), date sent to the fda: 4/7/2021.Corrected information: d3.
|
| |
|
Search Alerts/Recalls
|
|
|