DEPUY IRELAND - 9616671 ATTUNE PS FB INSRT SZ 6 10MM; ATTUNE IMPLANT : KNEE TIBIAL INSERT Back to Search Results
Model Number 1516-40-610
Medical Device Problem Code Adverse Event Without Identified Device or Use Problem (2993)
Health Effect - Clinical Code Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available (4581)
Date of Event 12/07/2017
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
(b)(4).Initial reporter occupation: lawyer.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event or Problem Description
Medical records ad 02 feb 2021 was reviewed.On (b)(6) 2016, the patient had a conversion from uni-compartmental arthroplasty of the right knee to total knee arthroplasty.Indications for surgery included pain.During the procedure the knee joint revealed severe tricompartmental arthritic changes and uni-compartmental medially there was loosening.Depuy components including depuy patella and depuy cement x2 were used during this procedure.There was no mention of the manufacturer of the previously implanted uni.On (b)(6) 2017, the patient had a revision right total knee arthroplasty to right infected total knee.All components including the patella were revised.Depuy components were implanted during this procedure, including depuy cement x3.Doi: (b)(6) 2016.Dor: (b)(6) 2017 (right knee).
 
Additional Manufacturer Narrative
Product complaint # (b)(4).Investigation summary : no device associated with this report was received for examination.A worldwide complaint database search found no other related reported incidents against the provided product code/lot number combination since release for distribution.Based on previous investigations, this complication of joint replacement is unlikely to have been the result of a device failing to meet required specifications.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Device history lot : the product investigation found no evidence suspecting an error in the manufacturing or material that would be a contributing factor in the reported allegation(s).Where the lot code was provided, a manufacturing records evaluation (mre) was not performed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ATTUNE PS FB INSRT SZ 6 10MM
Common Device Name
ATTUNE IMPLANT : KNEE TIBIAL INSERT
Manufacturer (Section D)
DEPUY IRELAND - 9616671
loughbeg ringaskiddy co.
cork
EI 
MDR Report Key11413537
Report Number1818910-2021-04386
Device Sequence Number14320522
Product Code NJL
UDI-Device Identifier10603295050100
UDI-Public10603295050100
Combination Product (Y/N)N
Initial Reporter StateTX
Initial Reporter CountryUS
PMA/510(K) Number
K111433
Number of Events Summarized1
Summary Report (Y/N)N
Device Implanted Year2016
Device Explanted Year2017
Serviced by Third Party (Y/N)Unknown
Reporter Type Manufacturer
Report Source other
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 02/23/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Operator of Device No Information
Device Expiration Date09/30/2019
Device Model Number1516-40-610
Device Catalogue Number151640610
Device Lot Number589594
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 02/23/2021
Supplement Date Received by Manufacturer04/07/2021
Initial Report FDA Received Date03/04/2021
Supplement Report FDA Received Date04/07/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Concomitant Medical Products
and Therapy/Usage Dates
ATTUNE FB TIB BASE SZ 5 CEM; ATTUNE MEDIAL DOME PAT 38MM; ATTUNE PS FB INSRT SZ 6 10MM; ATTUNE PS FEM RT SZ 6 NAR CEM; SMARTSET GHV GENTAMICIN 40G; SMARTSET GHV GENTAMICIN 40G; ATTUNE FB TIB BASE SZ 5 CEM; ATTUNE MEDIAL DOME PAT 38MM; ATTUNE PS FB INSRT SZ 6 10MM; ATTUNE PS FEM RT SZ 6 NAR CEM; SMARTSET GHV GENTAMICIN 40G; SMARTSET GHV GENTAMICIN 40G
Outcome Attributed to Adverse Event Required Intervention;
Patient Age62 YR
-
-