|
Investigation results: as of the date of this report the complaint product was not provided for investigation.Therefore, a thorough investigation is not possible.The device quality and manufacturing history records (dhr) have been checked for all available lot numbers and the products found to be according to our specification valid at the time of production.Two further incidents have been filed with the same lot regarding implant loosening until today.A clear root cause conclusion cannot be drawn due to the non-availability of important information and the device itself.The conclusion from the root cause analysis is that a systematic device deviation is unlikely, since the received complaints are limited to certain health care institutions and their applicants.The participation of the applicants in this deviation scenario cannot be excluded by today.Based on the root cause analysis result no corrective actions have been carried out.As a preventive action we were in contact with the affected health care institutions and applicants in order to reduce the probability of recurrence.The complaints were submitted to aesculap ag as a summary report.In order to examine further actions, all cases from the summary report are processed as vigilance suspicion cases and are continuously monitored.
|
|
It was reported that there was an issue with vega knee implant(s).It was reported on (b)(6) 2018 that as a result of having the product implanted, the patient has experienced patient experienced pain, swelling, difficulty walking, and loosening of the implant which resulted in a revision surgery.The primary surgery occurred on (b)(6) 2013 and the revision surgery occurred on (b)(6) 2015.All available information has been provided at this time; if additional information becomes available the complaint will be updated accordingly.The adverse event is filed under xc reference (b)(4).Involved components: nx053z (as vega ps tibial plateau).Nx031z (ps femur cemented f5n rt).Nx121 (ps pe insert t2/t2+, 12mm).Nn260p (peek plug f/ tibia).Nx043 (universal patella p3).The cement used was unknown.Associated medwatches: 2916714-2020-00324, 2916714-2020-00325, 2916714-2020-00326, 2916714-2020-00327.
|