• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: SMITH & NEPHEW, INC. 7.0X105MM CANN SC SS 16TD; PLATE, FIXATION, BONE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

SMITH & NEPHEW, INC. 7.0X105MM CANN SC SS 16TD; PLATE, FIXATION, BONE Back to Search Results
Model Number 71127105
Medical Device Problem Code Incorrect Measurement (1383)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/11/2021
Type of Reportable Event Serious Injury
Additional Manufacturer Narrative
Internal complaint reference number: (b)(4).
 
Event or Problem Description
It was reported that during surgery for neck of femur using smith and nephew chs system, the surgical team decided to use the anti-rotation screw treatment with smith and nephew 7.0mm cannulated screw system.Following correct positioning of the 3.2mm x 300mm threaded guide pin, a measurement was taken using the 6.5/8.0mm direct measuring gauge.Registrar read 105mm from end of the guide pin and requested a 7.0mm x 105mm cannulated screw 16mm thread stainless steel to be opened for use.During insertion of the 105mm screw, it was noted that the 105mm screw was approx 10mm too long.A 7.0mm x 95mm cannulated screw 16mm thread was then requested and inserted over the guide pin.The 95mm screw was noted to be of the correct length.Finally, the chs implantation was then completed with a surgical delay of less than 30 minutes and no injury to the patient.All available information has been disclosed.If additional information should become available, a supplemental report will be submitted accordingly.
 
Additional Manufacturer Narrative
The associated device, used in treatment, was returned and evaluated.A visual inspection of the returned device does not confirm the stated failure mode.A dimensional evaluation of the returned device does not confirm the stated failure mode.The device meets dimensional specification.The device is in tolerance.The clinical/medical evaluation concluded that this case reports that the cannulated screw system was used during the surgical procedure.The direct measuring gauge was used to measure the length of screw needed.During insertion, the screw was noted to be approximately 10mm too long.A second screw which was 10mm shorter was then used and noted to be the correct length.The procedure was completed with a minimal surgical delay and no injury to the patient.Therefore, no further clinical assessment is warranted at this time.A review of complaint history did not reveal additional complaints for the listed batch.A review of the manufacturing records did not reveal a manufacturing abnormality that could have caused or contributed to the reported incident.At this time, we do not have reason to suspect that the product failed to meet any product specifications at the time of manufacture.A review of the risk management file and instructions for use documents revealed this failure mode and potential harm was previously identified.Possible causes could include but not limited to user/procedural variance.Based on this investigation, the need for corrective action is not indicated.Should additional information be received, the complaint will be reopened.No further investigation is warranted for this complaint; however, we will continue to monitor for future complaints and investigate as necessary.We consider this investigation closed.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
7.0X105MM CANN SC SS 16TD
Common Device Name
PLATE, FIXATION, BONE
Manufacturer (Section D)
SMITH & NEPHEW, INC.
1450 brooks rd.
memphis TN 38116
MDR Report Key11444215
Report Number1020279-2021-01910
Device Sequence Number14472159
Product Code HRS
UDI-Device Identifier03596010175816
UDI-Public03596010175816
Combination Product (Y/N)N
Initial Reporter CountryAS
PMA/510(K) Number
K993106
Number of Events Summarized1
Summary Report (Y/N)N
Serviced by Third Party (Y/N)N
Reporter Type Manufacturer
Report Source company representative,foreig
Initial Reporter Occupation Physician
Type of Report Initial,Followup
Report Date (Section B) 08/23/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number71127105
Device Catalogue Number71127105
Device Lot Number19ET22136
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/16/2021
Initial Date Received by Manufacturer 02/11/2021
Supplement Date Received by Manufacturer08/23/2021
Initial Report FDA Received Date03/09/2021
Supplement Report FDA Received Date08/23/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
Outcome Attributed to Adverse Event Required Intervention;
-
-