Model Number 7601-N90003-M
Medical Device Problem Code Mechanical Jam (2983)
Health Effect - Clinical Code No Clinical Signs, Symptoms or Conditions (4582)
Date of Event 02/10/2021
Type of Reportable Event Malfunction
Event or Problem Description
A company representative reported that a yukon navigated screw inserter tip was jamming during surgery and could not be disconnected from the screw.The surgery was completed successfully following an unspecified delay with no adverse consequence to the patient.
 
Additional Manufacturer Narrative
Visual, dimensional, material and functional analysis could not be performed as the device was not returned.Device and complaint history records review could not be performed as a valid lot code was not provided and could not be obtained.Since the device was not returned, an exact cause of the reported event could not be determined.Inserting the screw with more force than normal, on a bone, can compound torsional forces at the screw/inserter interface, compromising the insertion feature of the screw head.As mentioned in the product ifu, to fully seat the inserter into the screw-head, the inserter has to be completely aligned with the screw.Ensuring that the screw is securely engaged in the inserter tip can assist in distributing forces evenly throughout the screw/inserter interface, reduce torque overloading, and reduce failures as reported.
 
Event or Problem Description
A company representative reported that a yukon navigated screw inserter tip was jamming during surgery and could not be disconnected from the screw.The surgery was completed successfully following an unspecified delay with no adverse consequence to the patient.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
NAVIGATED CERVICAL SCREW INSERTER; YUKON
Common Device Name
ORTHOPEDIC STEREOTAXIC INSTRUMENT
Manufacturer (Section D)
K2M, INC.
600 hope parkway se
leesburg VA 20175
MDR Report Key11446072
Report Number3004774118-2021-00069
Device Sequence Number17018428
Product Code OLO
UDI-Device Identifier10888857415973
UDI-Public10888857415973
Combination Product (Y/N)N
Initial Reporter StateCT
Initial Reporter CountryUS
PMA/510(K) Number
K201006
Number of Events Summarized1
Summary Report (Y/N)N
Reporter Type Manufacturer
Report Source company representative
Initial Reporter Occupation Other
Type of Report Initial,Followup
Report Date (Section B) 06/29/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Operator of Device Health Professional
Device Model Number7601-N90003-M
Device Catalogue Number7601-N90003-M
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Initial Date Received by Manufacturer 02/10/2021
Supplement Date Received by Manufacturer05/31/2021
Initial Report FDA Received Date03/09/2021
Supplement Report FDA Received Date06/29/2021
Is This a Single-Use Device that was
Reprocessed and Reused on a Patient? (Y/N)
No
Patient Sequence Number1
-
-